Quote list0
Your product list is empty!

Products

Results 61 - 90 of 102
Show per page
  • Animal
    Rat
    Videotracking
    Infrared

    To perform Light/Dark Test with rats or mice for assessing anxiety. Useful in identifying and/or screening of anxiolytic and anxiogenic agents.

    High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent comfort. Easy to set up, easy to clean.

  • Animal
    Mouse
    Videotracking
    Infrared

    To perform Light/Dark Test with rats or mice for assessing anxiety. Useful in identifying and/or screening of anxiolytic and anxiogenic agents.

    High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent comfort. Easy to set up, easy to clean.

  • Animal
    Rat
    Videotracking
    Infrared
    Elevated Zero Maze on LUX Front view

    The Elevated Zero-Maze is an alternative model to the Elevated Plus Maze (EPM). Its circular design provides a smoother transition from closed to open space. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.

    High quality maze with surface texture selected...

  • Animal
    Mouse
    Videotracking
    Infrared
    IR Elevated Zero-Maze for Mice over the Ugo Basile LUX 100 (580 nm)

    The Elevated Zero-Maze for mouse IR version, is an alternative model to the Elevated ZERO Maze (EZM) for mouse.
    It's completely built using a special plastic IR transparent material, legs including.
    Using a bottom IR illumination (the Ugo Basile LUX 100) and an IR video camera for video tracking, the set-up, gives You the possibility to perform EZM test in darkness with a perfect hight...

  • Animal
    Rat
    Videotracking
    Infrared
    Traditional, Infrared
    Infrared transparent Elevated Plus Maze

    The elevated plus maze (EPM) is used to measure anxiety in rats and mice. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.

    High quality maze with surface texture selected for best rodent comfort. Optimized for use with video tracking software (high...

  • Animal
    Mouse
    Videotracking
    Infrared
    Infrared transparent Elevated Plus Maze for mice

    The elevated plus maze (EPM) is used to measure anxiety in rats and mice. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.

    High quality maze with surface texture selected for best rodent comfort. Optimized for use with video tracking software (high...

  • Animal
    Mouse, Rat
    Videotracking
    Infrared

    The Open Field is used to assess exploratory behavior. Validated for use in the measurement of anxiety related behaviors. Also suited to the novel object recognition (NOR) test.

    Decreased anxiety leads to increased exploratory behavior. Increased anxiety results in less locomotor motion and preference for the edges of the field.

  • Animal
    Mouse, Rat, Other

    Convenient, cost-effective solution to confine rodents and small animals for anesthesia procedures.

    Models available in 2 sizes – smaller model for rodents and larger model for rabbits and similarly sized animals. Clear Perspex with a sliding lid. Quick connection to anesthesia or euthanasia systems using the 2 tubing connectors.

  • Animal
    Mouse, Rat
    Librae Incapacitance tester with Rat restrainer. Notice the foot pedal in case the experimenter wants to start/stop the test manually

    Measures the weight distribution difference between an injured and unaffected hind paw of a mouse or rat. For the assessment of spontaneous pain in osteoarthritis, bone cancer, nerve injury and post-operative pain studies. Automatic operation reduces operator bias, optimizes repeatability and saves time. Easy to set up. Data visualization to monitor trends. Fast and easy cleaning...

  • Animal
    Mouse, Rat

    Provides simple, reliable and precise calibration for Ugo Basile Plantar Test & Tail Flick and other infrared (I.R.) analgesia meters.

  • Animal
    Mouse, Rat
    Hot/Cold Plate - Screening of Thermal Hyperalgesia/Allodynia

    The hot cold plate test has been the gold standard test for thermal pain tests in rodents for decades. Through the years the devices have been improving and the techniques have become more sophisticated, adding to constant temperature methods also other ones.

    The Ugo Basile Hot/Cold plate test includes all the latest technologies necessary to run constant temperature, linear ramping...

  • Animal
    Mouse, Rat

    Studies natural curiosity and exploration behavior of rodents when confronted with a new environment (head-plunging, or nose-poking stereotype) according to the method devised by Boissier-Simon. For testing effects of psychotropic drugs on exploratory behavior.

    The Boards are available with opaque or transparent walls for use with video tracking software. Mouse or rat versions.

  • Animal
    Mouse, Rat

    The Grip Strength Meter determines the maximum force displayed by an animal in the forelimb, hind-limb or all four limbs, thanks to the full set of accessories included in the Ugo Basile Grip Strength Meter package.

    The technique exploits the instinctive resistance of rodents to backward movements and their consequence tendency to grasp (grip) against the pull-back...

  • Animal
    Mouse, Rat
    Videotracking
    Traditional

    Automatically scores wheel rotations, corresponding to rodent escape behaviors. A primary screening test for antidepressants.

    Automates up to 40 tests simultaneously for high throughput. Durable, easy to assemble. Optimized for use with video tracking software.

  • Animal
    Mouse, Rat
    Fear Conditioning System. Cubicle front view with door open and animal cage with checkerboard contexts mounted

    The Ugo Basile Fear Conditioning system is composed of:

    • Isolation cubicle, including all electronics, fan, IR/VIS lights, camera (up to 16 cubicles can be connected to 1 PC)
    • The animal cage is available in different dimensions for rats and mice, plus the observational learning version to allow two animals to see each other. The standard...
  • Mouse RotaRod black enlarger with grooves, mounted on a Mouse RotaRod

    Enlargers for Mouse and Rat RotaRod are available to add multiple parameters to change the complexity of the experiment. Enlargers add-on for RotaRod come with grooves to increase the diameter of the rod or in smooth rubber to increase the diameter of the rod and change the surface from a grooved one to a smooth one. All the types of enlargers can be easily added to the rotating drum thanks to...

  • Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The Elevated Zero-Maze is an alternative model to the Elevated Plus Maze (EPM). Its circular design provides a smoother transition from closed to open space. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.

    High quality maze with surface texture selected...

  • Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The elevated plus maze (EPM) is used to measure anxiety in rats and mice. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.

    High quality maze with surface texture selected for best rodent comfort. Optimized for use with video tracking software (high...

  • Animal
    Mouse, Rat

    Touch sensitivity in unrestrained animals is traditionally tested with Von Frey filaments, which is a tedious and experimenter-dependent assay.

    The Electronic Von Frey system solves the multiple measurement (i.e. multiple filaments) issue and the experimenter bias by using a hand-held force sensor with a rigid metal. The scientist gradually increases the force applied to the animal...

  • Animal
    Mouse, Rat

    Provides precise information on the optimum day for mating during estrous cycle in the rats.

    A powerful tool for improving reproduction efficiency. Simple, quick operation. Automatically calibrated when turned on. Designed for rats. A probe is available for mice.

  • Electric Schock Meter

    An essential instrument to measure current on Ugo Basile devices using electric shock grid, such the Fear Conditioning System, Active an Passive avoidance system.

    Give the research the ability to measure the electric shock current not measurable by a common volt-meter. To ensure that the same current is delivered on multiple electric shock grids, while performing multiple test in...

  • Animal
    Mouse, Rat

    Designed for inducing convulsions in research mice and rats for epilepsy studies and many more e.g., neurochemical and neuropharmacological research such as evaluating the depressant or stimulating action of drugs on the CNS.

    Reproducible results. Parameters have been selected as the most suitable range for mice or rats. Flexibility to extend your experiments by adding other...

  • Animal
    Mouse, Rat
    Dynamic Plantar Aesthesiometer Full Front Upper View

    Touch sensitivity is traditionally tested with Von Frey filaments, which is a tedious and experimenter-dependent assay.

    The Dynamic Plantar Aesthesiometer is a unique system, which fully automates the amount of force applied by an electromagnetic, silent motor exerting from 0 to 100 grams at a rate adjustable from 0 to 50 seconds.

    When the animal responds, by withdrawing its...

  • Animal
    Rat
    The Durham Holders are new rat holders for trigeminal stimulation, the newest accessory for use with the Plantar Test and Dynamic Plantar Aesthesiometer, manufactured by Ugo Basile.
  • Animal
    Mouse
    Videotracking
    Traditional

    The Delta-maze is a custom modification of the T-maze, a special design made possible by the extreme adaptability of our MultiMaze system 41500. The newest scientific research approaches, based on the available current technologies, often combine different methods in the same test in order to obtain more detailed and more interesting data.  As an example, more and more often scientists need to...

  • Animal
    Other

    Provides accurate recording of isometric or isotonic tissue contraction/release. For studying effects of drugs or electrical stimuli on isolated smooth muscles (including uterus, trachea, gastrointestinal tract, vessel strips, auricle etc) under optimum conditions.

    Classic pharmacology tool for research and teaching. Maintains the integrity of live muscle tissue for several hours in...

  • Animal
    Mouse, Rat

    A 2-compartment box that offers visual and tactile differences. For evaluating the abuse potential of substances and the motivational effects of drugs in mice or rats.

    Interchangeable floors, optimized for use with video-tracking software or visual scoring, thanks to the grey, high-contrast color and non-smooth, non-reflective paint.

  • Mouse RotaRod with Complex Wheel

    The complex wheel add-on for mouse and rat RotaRod introduces an additional complexity element for the animal to be tested. Thanks to the asymmetrical and adjustable bars it increases the test sensitivity and add a higher involvement of motor cortex and hippocampus, as compared to the classic rotarod test.

    The Ugo Basile RotaRod is the 1st and original, invented after the Dunham and...

  • Animal
    Mouse, Rat

    Provides and easy to use means of immobilizing an animal for surgery or procedures such as imaging. Gas Anesthesia (compared to injections) is a very quick way to induce total unconsciousness and also assists fast recovery.

    High quality compact, modular and virtually unbreakable system. Reliable and precise delivery of the anesthetic gas to animals. Expandable system providing...

  • Animal
    Mouse
    Climbing Test front view. he system is composed of 4 channel electronic unit, climbing cylinder and ceiling

    Climbing behavior can be of interest for the most diverse applications.

    The Ugo Basile automated system replicates its first manual application in the Pain field, for measuring Pain-Depressed behavior. It showed that, while mild analgesics block pain-depressed climbing, strong analgesics fail to alleviate depression of climbing (Santos et al. 2023, “Climbing behavior by mice as an...