Quote list0
Your product list is empty!


Rodent Ventilator – Volume Controlled

Product Code:7025/7125

A positive pressure pump (according to Starling’s Ventilator method) for small animals. Assists with breathing during anesthesia and surgery or when an animal has an injury or illness that requires respiratory support.

Highly accurate, rate displayed digitally, choice of cylinder/piston assemblies (from 0.05-0.5 ml to 20-100 ml), quiet, high quality, robust with a long lifetime. Options include Start/Stop model for advanced electrophysiological-pharmaco­logical investigations.

Model
Choose a model to get a quote...
An extended warranty can be added for most Ugo Basile products. You can find this information in the ordering information section of each product.
To learn more about the extended warranty, CLICK HERE

Background

  • Assists or stimulates respiration in a subject which is not breathing or is unable to make sufficient respiratory effort on its own.
  • Mechanical ventilation is a method to assist or replace spontaneous breathing.
  • For use with small animals including guinea pigs, rats, mice and small birds.

 Highly accurate, quiet, low maintenance, long life span

  • Highly accurate and reliable stroke rate for providing consistent volumes. Uses a variable speed geared motor (with no backlash) linked by a novel variable stroke mechanism. Volume is adjustable whether the pump is running or stationary. 
  • Stroke rate (per minute) is indicated on the 3-digit LED display. 
  • Caters for different sized animals with easily interchangeable 5ml, 10ml or 30ml cylinder/piston assembly. 
  • Flexibility in air channeling with four ports (Intake, To Animal, From Animal and Exhaust). Input can be room air or any other non-explosive gas mixture. Exhaust air may be partially or totally recycled or collected for analysis. 
  • Quiet operation. High quality and robust. Low sliding friction for practically no wear or tear for a long lifetime. 
  • Operation may be "paused" by an external TTL logic signal, such as a digital output from a data acquisition or imaging system.
  • Select Start/Stop Model for advanced electrophysiological-pharmacological investigations.
  • Product review: “We have four of your respirators in our extended lab and they are wonderful – as is your service” Dr. Nicholas Price, Monash University, Australia

Artificial ventilation, also called artificial respiration is any means of assisting or stimulating respiration in a subject which is not breathing or is not making sufficient respiratory effort on its own.
Mechanical ventilation is a method to mechanically assist or replace spontaneous breathing: this involves a machine called a ventilator.

Features

Benefits

Interchangeable cylinder/piston

5, 10, 30ml max stroke volume

Reliable mechanics

Lifelong lasting, virtually zero maintenance

Silent operation & negligible R.F. broadcasting

Quiet operation, both acoustically and electrically

External TTL to Pause the ventilator

Quick connection to external devices

Optional  Synchronized START/STOP  for demanding electrophysiology tests

Ideal for gas anesthesia or euthanasia procedures

General

Rate

10 to 180 strokes for minute

Rate Read-out

On digital display

Stroke Volume

0.5 to 5; 1 to 10 or 3 to 30 ml, depending on cylinder/piston installed

Stroke Volume Scale

Double indication 1-10 & 3-30 ml

Stroke Volume Reproducibility

±2%

Power Requirement

Universal input 85-264 VAC, 50-60Hz, 40 VA max.

Operating Temperature

5°to 30°C

7025 Start-Stop

via TTL command

7125 by synchronised command

Sound Level

<70dB

Physical

Dimensions

27x26x19cm

Weight

9.5Kg

Shipping Weight

16 Kg approx.

Packing Dimensions

67x42x53cm

Warranty

Warranty Rodent Ventilator is covered by a 12-month warranty + 12 after product registration
UB-Care Additional UB-Care can be added for other 12 or 24 months

7025 Rodent Ventilator, complete with 10ml cylinder/piston assembly

7026

10ml Cylinder/piston assembly, complete 

7032

Perspex Lid

7033

Lithium-Grease Tube

7044

Y-Cannula

E-AU 041

USB pen drive, including

7025-302 Instruction Manual 

Other available Models

7025-1

Rodent Ventilator, with 1ml cylinder/piston assembly

7025-5

Rodent Ventilator, with 5ml cylinder/piston assembly

7025-30

Rodent Ventilator, with 30ml cylinder/piston assembly

Models with Synchronized START/STOP circuit

7125

Rodent Ventilator, with 10ml cylinder/piston assembly, synchronized

7125-1

Rodent Ventilator, with 1ml cylinder/piston assembly, synchronized

7125-5

Rodent Ventilator, with 5ml cylinder/piston assembly, synchronized

7125-30

Rodent Ventilator, with 30ml cylinder/piston assembly, synchronized

Accessories

7131

1ml Cylinder/piston assembly, complete with suitable link

7128

5ml Cylinder/piston assembly, complete with suitable link

7026

10ml Cylinder/piston assembly, complete 7032

7027

30ml Cylinder/piston assembly, complete

7025-150

Connection Kit for Anesthesia System to Ventilator 7025

 

See also our Anesthesia Systems, series 21100, the ideal match to our Ventilators

L.I. Kleinman and Edward P. Radford Jr: “Ventilation Standards for Small Mammals” J.Applied Physiol. 19: 360-362, 1964

Back to: Ventilators anesthesia