Quote list0
Your product list is empty!
Results 31 - 60 of 83
Show per page
  • Animal
    Mouse, Rat
    Hot/Cold Plate - Screening of Thermal Hyperalgesia/Allodynia

    The hot cold plate test has been the gold standard test for thermal pain tests in rodents for decades. Through the years the devices have been improving and the techniques have become more sophisticated, adding to constant temperature methods also other ones.

    The Ugo Basile Hot/Cold plate test includes all the latest technologies necessary to run constant temperature, linear ramping...

    Animal
    Mouse, Rat

    Provides simple, reliable and precise calibration for Ugo Basile Plantar Test & Tail Flick and other infrared (I.R.) analgesia meters.

    Animal
    Mouse, Rat
    Librae for Rats with Adjustable Restrainer (SKU 47880-004)

    Measures the weight distribution difference between an injured and unaffected hind paw of a mouse or rat. For the assessment of spontaneous pain in osteoarthritis, bone cancer, nerve injury and post-operative pain studies. Automatic operation reduces operator bias, optimizes repeatability and saves time. Easy to set up. Data visualization to monitor trends. Fast and easy cleaning...

  • Animal
    Mouse, Rat, Other

    Convenient, cost-effective solution to confine rodents and small animals for anesthesia procedures.

    Models available in 2 sizes – smaller model for rodents and larger model for rabbits and similarly sized animals. Clear Perspex with a sliding lid. Quick connection to anesthesia or euthanasia systems using the 2 tubing connectors.

    Animal
    Other

    Provides accurate recording of isometric or isotonic tissue contraction/release. For studying effects of drugs or electrical stimuli on isolated smooth muscles (including uterus, trachea, gastrointestinal tract, vessel strips, auricle etc) under optimum conditions.

    Classic pharmacology tool for research and teaching. Maintains the integrity of live muscle tissue for several hours in...

    Animal
    Mouse, Rat

    The cubicle is a sound-attenuating chamber that isolates small animal subjects from distracting ambient light, sound and activity. For behavioral studies including operant behavior (Skinner), self-administration, etc.

    High-level soundproof efficacy, noiseless fan, control box. Extra fixtures (speaker and video camera holder) for fear conditioning studies. Available in standard, large...

  • Animal
    Other

    Measures the force (or tension) of isolated tissue when its length is constant. Pharmacological responses can be characterized by the contractile/relaxant properties.

    Four models available covering range from 0 to 50g. Highest-sensitivity model covers the range 0-800mg. Sturdy construction. Connects to popular data acquisition systems.

    Animal
    Other

    For investigating isotonic contractions (changes in tissue length) of isolated muscles and measuring small displacements in physiological preparations. Typically used to study the contractile/relaxation effects of drugs.

    Perfect for studies using extremely small and fast muscle fibers. Set up a comprehensive system by adding our data acquisition system, organ baths, electrodes and...

    Animal
    Mouse, Rat

    The KDS Legato series is a range of advanced, precision syringe pumps. For applications requiring high metering precision at low, pulse-free flow rates.

    Intuitive touch screen allows user to easily define complex injection protocols. Display presents real time data.

  • Animal
    Mouse, Rat

    The flexible rodent Lickometer - Vogel Test can operate as both a simple software-based lickometer as well as a system for drinking-conflict experiments (coupled with electric shocks). For assessing anxiety and the anxiolytic effect of drugs.

    Rat and mouse models. Easy data collection within the included software for windows. Up to 5 cages can be managed by 1 PC.

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    To perform Light/Dark Test with rats or mice for assessing anxiety. Useful in identifying and/or screening of anxiolytic and anxiogenic agents.

    High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent comfort. Easy to set up, easy to clean.

    Animal
    Mouse, Rat

    Compact, direct current (DC) Lesion Maker for localized electrolytic lesions in the brain.

    Isolated, regulated DC output for electrical safety. Two operating modes: Continuous and Timed.

  • Animal
    Mouse, Rat
    Videotracking
    Infrared

    The LUX Infrared (IR) illuminator allows for illumination from below of all the Ugo Basile IR mazes, which are made of an IR translucent plastic. This has the double advantage of: making experiments in the darkness easy and enhancing the contrast for better detection, no matter the animal color

    The lux is available in 3 sizes, it guarantees a uniform illumination and incorporates IR...

    Animal
    Mouse, Rat

    Untainted, reliable samples enabled by a unique funnel and cone design that effectively separates rodent feces and urine into tubes outside the cage.

    Collection tubes are easy to remove and the process will not disturb the animals.

    Animal
    Mouse

    A positive pressure pump (according to Starling's Ventilator method) for mice. Assists with breathing during anesthesia and surgery or when an animal has an injury or illness that requires respiratory support.

    Highly accurate, rate displayed digitally, quiet, durable, high quality, long lifetime. Up to 300 strokes/min. Optimizes oxygenation by minimizing dead space. Range of...

  • Animal
    Mouse, Rat

    Patented non-invasive vital signs monitor. Measures heart rate, arterial oxygen saturation (SpO2), breath rate, and temperature (optional) of anesthetized and conscious small laboratory animals of various sizes.

    Clinically validated and cited in a range of published studies including respiratory, neonatal, hypertension and brain injury.

    Animal
    Mouse, Rat
    Videotracking
    Traditional

    Versatile, automated modular device empowers researchers to assemble a custom configuration perfectly suited to spatial learning and spatial memory studies in rats or mice.

    The same modular device can be transformed into automated radial, Y and T mazes by simply rearranging the arms.

    Surface texture is selected for best rodent comfort as well as optimal results with video...

    Animal
    Mouse, Rat

    When rodents are exposed to inescapable and unpredictable stress, such as forced swim or inescapable foot shock, they often develop deficits in memory and learning tasks (e.g. Active Avoidance) and they often show analgesic reactions (S.I.A. Stress-Induced Analgesia).

    The Ugo Basile Set-Up for Learned Helplessness is based on a sophisticated generator of unpredictable random shocks...

  • Animal
    Other

    A powerful complement to any stimulator. Delivers pulses for up to four preparations simultaneously. Adjustable polarity and intensity for each channel.

    Animal
    Mouse
    Videotracking
    Traditional

    Automatically scores wheel rotations, corresponding to rodent escape behaviors. A primary screening test for antidepressants.

    Automates up to 40 tests simultaneously for high throughput. Durable, easy to assemble. Optimized for use with video tracking software.

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared
    Set of white NOR with differet shapes (cube, pyramid, cylinder and sphere) in an open fields

    The object recognition test is now among the most commonly used behavioral tests for memory studies in rodents. In its simplest design, an animal is presented with two similar objects during the first session and then one of the two objects is replaced by a new object during a second session or is moved to a different location.

    This test is based on the spontaneous tendency of rodents...

  • Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The Open Field is used to assess exploratory behavior. Validated for use in the measurement of anxiety related behaviors. Also suited to the novel object recognition (NOR) test.

    Decreased anxiety leads to increased exploratory behavior. Increased anxiety results in less locomotor motion and preference for the edges of the field.

    Animal
    Mouse
    Videotracking
    Traditional, Infrared
    Operant Fear Conditiong Cage in a Fear Conditioning Isolation Cubicle, view of the operant wall

    The Operant Fear Conditioning Cage couples a classic skinner box with sound and light cues for complex experiments, as well as standard operant tests and fear conditioning protocols.

    Animal
    Mouse
    Operon Full System complete with Olfactrory Delivery System and Air Control System for Operon

    Set-shifting task has proven to be an effective preclinical tool for drug testing and genetic screening, with direct translational valence in healthy humans and patients with schizophrenia.

    The Ugo Basile Operon automatizes the Intra-/Extra-dimensional (ID/ED) attentional set-shifting battery of tests offering visual, olfactory and tactile stimulations, all controlled by software and...

  • Animal
    Rat

    Measures hypersensitivity to thermal (hot and cold) and/or mechanical stimulation of the orofacial area in rats (mouse adaptor available). For research into a wide range of pain conditions involving the trigeminal nerve.

    High throughput with data recorded from up to 16 cages with ORO-Software. Real time data display. Non-invasive, respectful test. Comprehensive metrics and easy data...

    Animal
    Mouse, Rat
    38500-001 PAM Electronic Unit, with sensor
    The P.A.M. (Pressure Application Measurement) device is an original tool designed for measuring mechanical pain threshold on joints. It was specifically designed and validated for Arthritis research and is therefore especially suited to assess joint hypersensitivity in rodent knees or ankles. Once saved, data can be browsed on the control unit and/or transferred to a PC in proprietary, Excel or...
    Animal
    Mouse

    A classic way to assess short or long-term memory in small laboratory animals (rodents) using a fear-motivated avoidance task. Used routinely in animal model studies of aging and Alzheimer-type dementia, including the search for new therapeutic drugs.

    An efficient, reliable instrument for use with mice (or small rats). A silent, automated sliding door divides compartments. Precision...

  • Animal
    Mouse, Rat

    Passive Avoidance Test is used to assess memory function based on the association formed between a specific environmental context, which the animal learns to avoid and an aversive stimulus – represented by a mild foot shock.

    Efficient and reliable. Silent, automated sliding door divides the dark and light compartments. Systems for mice or rats. Manage up to 4 cages with one...

    Animal
    Mouse, Rat
    Pellet Dispenser on fully automated Multi-Maze, without manger, lateral close up

    The Ugo Basile Pellet Dispenser works with pellets between 10-20 mg for mice and 22-45 mg for rats. It has an extremely high delivery accuracy thanks to the redundant photobeam check.

    An embedded electronic board manages the DC motor and the photodiodes. An ethernet cable connects the Pellet Dispensers to the 8 channel control unit to independently manage up to 8 pellet...

    Animal
    Mouse, Rat
    Plantar Test for Thermal Stimulation Hargreaves Apparatus frontal view

    In the late ‘80s Dr. Hargreaves invented a method to assess thermal pain sensation in unrestrained rodents by stimulating the single hind paw and thus allowing for unilateral/contralateral experiments. Ugo Basile made a science-grade instrument to perform this stimulation and automatically measure response, it became a gold-standard with more than 2,000 publications in 2022.

    A thermal...

Filters