Quote list0
Your product list is empty!
Results 1 - 30 of 38
Show per page
  • Animal
    Mouse, Rat

    In the late ‘80s Dr. Hargreaves invented a method to assess thermal pain sensation in unrestrained rodents by stimulating the single hind paw and thus allowing for unilateral/contralateral experiments. Ugo Basile made a science-grade instrument to perform this stimulation and automatically measure response, it became a gold-standard with more than 2,000 publications in 2022.

    A thermal...

    Animal
    Mouse
    The mouse can freely move in the circular external lane base on his thermal preferences

    The TGR can clearly discriminate temperature-dependent phenotypes or temperature dependent drug effects.

    It records and analyses thermal preference phenotyping in mice. For neuropathic pain studies, peripheral neuropathy, temperature sensitivity and insensitivity assessment in basic research, phenotyping and drug screening.

    The animal is freely moving, its position is tracked...

    Animal
    Mouse, Rat

    Measures endurance, distance and speed. For studying behavioral, physiological, biochemical, and molecular responses to both acute exercise stress and chronic exercise training.

    Original product by Ugo Basile is adaptable for use by rats or mice. Easy set up and control using touch screen. Automatic measurement of endurance, distance and speed. Shock grid for aversive stimulus (if...

  • Animal
    Mouse, Rat
    Videotracking
    Traditional

    Versatile, automated modular device empowers researchers to assemble a custom configuration perfectly suited to spatial learning and spatial memory studies in rats or mice.

    The same modular device can be transformed into automated radial, Y, T and Delta mazes by simply rearranging the arms.

    Surface texture is selected for best rodent comfort as well as optimal results with...

    Animal
    Mouse, Rat
    Videotracking
    Traditional

    Fear conditioning is one of the most common methods to measure memory in rodents. It exploits the Pavlovian association between an unpleasant unconditioned stimulus (shock) to a conditioned neutral stimulus (sound cue). The reaction of rodents, as predated animals, is to freeze (stay immobile) when exposed to fearful situations, such as a shock.

    Once the association has happened and...

    Animal
    Mouse, Rat

    Pre-pulse inhibition of the Startle reflex (PPI) is a phenomenon in which a weak stimulus (sound or light, or air-puff) suppress the startle response to a subsequent stronger startle stimulus (of the same kind).

    The interest in this technique is mainly due to the fact that impairment in PPI is normally linked to a dysfunction in the sensorimotor mechanism, which has been shown in...

  • Animal
    Mouse, Rat

    Measures the weight distribution difference between an injured and unaffected hind paw of a mouse or rat. For the assessment of spontaneous pain in osteoarthritis, bone cancer, nerve injury and post-operative pain studies. Automatic operation reduces operator bias, optimizes repeatability and saves time. Easy to set up. Data visualization to monitor trends. Fast and easy cleaning...

    Animal
    Rat

    Measures hypersensitivity to thermal (hot and cold) and/or mechanical stimulation of the orofacial area in rats (mouse adaptor available). For research into a wide range of pain conditions involving the trigeminal nerve.

    High throughput with data recorded from up to 16 cages with ORO-Software. Real time data display. Non-invasive, respectful test. Comprehensive metrics and easy data...

    Animal
    Mouse, Rat
    Thermal Place Preference - complete system

    The Thermal Place Preference test can be considered an evolution of the Hot/Cold plate test and it allows monitoring of temperature preferences by measuring the time spent in two compartments set at two different temperatures.

    This two temperature nociception test can be used in a mouse or rat and is composed of a standard hot/cold plate and of an hot plate, connected by a corridor. It...

  • Animal
    Mouse, Rat

    This software enables researchers to study behavior in a more reliable and consistent way and over longer time periods than if they were using direct observation or manual recording.

    Highly advanced, comprehensive video-tracking system. The software couples an unrivalled depth of features with a simple, familiar design, to provide automated testing in virtually any behavioral...

    Animal
    Mouse, Rat

    Measures small changes in volume & oedema (fluid retention) to gauge the inflammatory response such as for anti-inflammatory screening tests.

    Hands-free operation. Precision measurements. Detects and displays 0.01 ml changes in rodent paw volume. Easy data transfer and software included.

    Animal
    Mouse, Rat

    Accurately measures the nociceptive threshold to infrared heat stimulus on the rat or mouse tail. Used for rapid screening of analgesic drugs by measuring reaction time to heat, even in anesthetized animals, crucial for repeated tests, thanks to the reflexive nature of the tail flick response.

    Adjustable I.R. intensity, bright touch-screen display with intuitive controls. Comfortable...

  • Animal
    Rat

    A positive pressure pump (according to Starling’s Ventilator method) for small animals. Assists with breathing during anesthesia and surgery or when an animal has an injury or illness that requires respiratory support.

    Highly accurate, rate displayed digitally, choice of cylinder/piston assemblies (from 0.05-0.5 ml to 20-100 ml), quiet, high quality, robust with a long lifetime....
    Animal
    Mouse, Rat

    A set up for testing active avoidance (also called automatic reflex conditioner or shuttle box), i.e. learning to predict the occurrence of an aversive event, based on the presentation of a specific stimulus. Enables performance of a wide range of avoidance experiments using a flexible schedule. Precise detection of avoiding aversive event. Manage up to 4 cages with one controller.

    Animal
    Mouse

    A positive pressure pump (according to Starling's Ventilator method) for mice. Assists with breathing during anesthesia and surgery or when an animal has an injury or illness that requires respiratory support.

    Highly accurate, rate displayed digitally, quiet, durable, high quality, long lifetime. Up to 300 strokes/min. Optimizes oxygenation by minimizing dead space. Range of...

  • Animal
    Other

    A positive pressure pump (according to Starling's Ventilator method) for cats, rabbits and small animals of similar size. Assists with breathing during anesthesia and surgery or when an animal has an injury or illness that requires respiratory support.

    Highly accurate rate displayed digitally, choice of cylinder/piston assemblies (50, 100 ml), quiet, robust, high quality, and long...

    Animal
    Mouse, Rat

    The cubicle is a sound-attenuating chamber that isolates small animal subjects from distracting ambient light, sound and activity. For behavioral studies including operant behavior (Skinner), self-administration, etc.

    High-level soundproof efficacy, noiseless fan, control box. Extra fixtures (speaker and video camera holder) for fear conditioning studies. Available in standard, large...

    Animal
    Mouse, Rat

    Provides and easy to use means of immobilizing an animal for surgery or procedures such as imaging. Gas Anesthesia (compared to injections) is a very quick way to induce total unconsciousness and also assists fast recovery.

    High quality compact, modular and virtually unbreakable system. Reliable and precise delivery of the anesthetic gas to animals. Expandable system providing...

  • Animal
    Mouse, Rat

    Passive Avoidance Test is used to assess memory function based on the association formed between a specific environmental context, which the animal learns to avoid and an aversive stimulus – represented by a mild foot shock.

    Efficient and reliable. Silent, automated sliding door divides the dark and light compartments. Systems for mice or rats. Manage up to 4 cages with one...

    Animal
    Mouse, Rat
    The P.A.M. (Pressure Application Measurement) device is the original tool designed for measuring mechanical pain threshold on joint. It was specifically designed and validated for Arthritis research and is therefore especially suited to assess joint hypersensitivity in rodent knees or ankles. Once saved, data can be browsed on the control unit and/or transferred to a PC in proprietary, Excel or...
    Animal
    Mouse, Rat

    Patented non-invasive vital signs monitor. Measures heart rate, arterial oxygen saturation (SpO2), breath rate, and temperature (optional) of anesthetized and conscious small laboratory animals of various sizes.

    Clinically validated and cited in a range of published studies including respiratory, neonatal, hypertension and brain injury.

  • Animal
    Mouse, Rat

    Invasive arterial or venous blood pressure measurement during animal surgery. For urodynamic, intrauterine and intracranial studies. Also suitable for intensive care.

    Connects to data acquisition systems such as our DataCapsule-Evo. High quality, robust, reusable and cost effective.

    Animal
    Mouse, Rat

    A multi-function, non-invasive blood pressure recorder for small to medium animals (mice to dogs) for use in a wide range of scientific studies.

    Combines functionality of multiple systems including pressure generation-pressure monitoring system, pulse amplifier, thermal-array analog and digital recording unit and more. Single turn-key, stand-alone solution that can also be connected...

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    To perform Light/Dark Test with rats or mice for assessing anxiety. Useful in identifying and/or screening of anxiolytic and anxiogenic agents.

    High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent comfort. Easy to set up, easy to clean.

  • Animal
    Mouse, Rat

    Measures the force on a rat or mouse paw according to the Randall-Selitto paw-pressure test, it enables rapid and precise screening of analgesic drugs for anti-nociceptive studies, in healthy or inflamed limbs. The device applies a steady increasing force, starting and stopping using the foot pedal. No calibration required. Digital model with force sensors and electronic unit is also...

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The Radial Arm Maze has 8 equally spaced arms radiating from a central circular compartment. It can be used for several sophisticated protocols to study spatial, working and reference learning and memory.

    The animal can rely on egocentric or allocentric strategies. Working versus reference memory can be assessed by adopting intra or inter trial protocols. Easy to set up, easy to...

    Animal
    Mouse, Rat
    Videotracking
    Traditional

    The Barnes Maze is a valid alternative to the water maze to study spatial learning and memory. The motivational drive is the rodent’s instinctive aversion for open spaces and natural preference for dark, “sheltered” spaces.

    Reliable and durable. Optimized for use with video-tracking software. Available for mice or rats. Easy to set up, easy to clean.

  • Animal
    Mouse, Rat

    When rodents are exposed to inescapable and unpredictable stress, such as forced swim or inescapable foot shock, they often develop deficits in memory and learning tasks (e.g. Active Avoidance) and they often show analgesic reactions (S.I.A. Stress-Induced Analgesia).

    The Ugo Basile Set-Up for Learned Helplessness is based on a sophisticated generator of unpredictable random shocks...

    Animal
    Mouse, Rat
    Videotracking
    Traditional

    Atlantis System allows platforms in a Morris Water Maze to rise gently to near the surface or go down automatically, using the manual controller or TTL signals. From one to four platform systems available.

    Enables extinction protocols on rats or mice. No need to stop the test to manually remove or reposition platforms.

    Animal
    Mouse, Rat
    Videotracking
    Traditional

    A test for spatial learning and long-term memory in rodents. For research into neurocognitive disorders and treatments, aging, drug-abuse, neural systems, neurotransmitters and brain development.

    High quality, strong and low weight. Embedded wheels for easy movement. Easy to drain and clean. Add optional Atlantis System to extend test capabilities. Different colors available.

Filters