Measures paw withdrawal latency in unrestrained and unhandled rodents during experiments, in response to an infrared heat stimulus. For studying pain sensitization and thermal pain response recovery.
Automatic detection of paw withdrawal for accuracy.
Automates the assessment of “touch sensitivity” on the plantar surface of rats or mice.
For assessment of hypersensitivity and allodynia for analgesia, nociceptive, neuropathic and postsurgical studies.
Unique automation features save significant time for the researcher.
Records and analyses thermal preference phenotyping in mice, according to Zimmermann's method. For neuropathic pain studies, temperature sensitivity and insensitivity assessment, always with the animal freely moving and with no user’s intervention.
Measures mechanical sensitivity thresholds. For the assessment of hypersensitivity and allodynia for analgesic, nociceptive, neuropathic and postsurgical studies. Original design with clear prism for fast localization of stimulation site and reduced animal stress. Digital data display.
Original design with clear prism for fast localization of stimulation site and reduced animal...
Screens thermal hyperalgesia and allodynia, conditions often observed in patients with neuropathic pain or inflammation. Also used for testing analgesic and anti-inflammatory drugs.
Fixed or increasing temperature (RAMP) modes for dynamic experiments. Reaches user-defined temperatures within minutes. Touch screen or X-PAD software for setting up and monitoring tests, including...
Measures the weight distribution difference between an injured and unaffected hind paw of a mouse or rat.
For the assessment of spontaneous pain in osteoarthritis, bone cancer, nerve injury and post-operative pain studies.
Automatic operation reduces operator bias, optimizes repeatability and saves time. Easy to set up. Data visualization to monitor trends. Fast and easy cleaning...
Measures hypersensitivity to thermal (hot and cold) and/or mechanical stimulation of the orofacial area in rats (mouse adaptor available). For research into a wide range of pain conditions involving the trigeminal nerve.
High throughput with data recorded from up to 16 cages with ORO-Software. Real time data display. Non-invasive, respectful test. Comprehensive metrics and easy data...
Identifies temperature sensitivity and nociceptive pain thresholds. For pathophysiological exploration of animal pain models and pharmacological assessment of analgesic drugs. Often called the Two-Temperature Choice Test.
Easy touch screen controls for setting up and monitoring tests. Fast data portability. Fixed or ramp temperatures for dynamic experiments.
Accurately measures the nociceptive threshold to infrared heat stimulus on the rat or mouse tail. Used for rapid screening of analgesic drugs by measuring reaction time to heat, even in anesthetized animals, crucial for repeated tests, thanks to the reflexive nature of the tail flick response.
Adjustable I.R. intensity, bright touch-screen display with intuitive controls. Comfortable...
Designed for inducing convulsions in research mice and rats for epilepsy studies and many more e.g., neurochemical and neuropharmacological research such as evaluating the depressant or stimulating action of drugs on the CNS.
Reproducible results. Parameters have been selected as the most suitable range for mice or rats. Flexibility to extend your experiments by adding other...
The P.A.M. (Pressure Application Measurement) device is the original tool designed for measuring mechanical pain threshold on joint. It was specifically designed and validated for Arthritis research and is therefore especially suited to assess joint hypersensitivity in rodent knees or ankles.
Once saved, data can be browsed on the control unit and/or transferred to a PC in proprietary, Excel or...
Measures the force on a rat or mouse paw according to the Randall-Selitto paw-pressure test, it enables rapid and precise screening of analgesic drugs for anti-nociceptive studies, in healthy or inflamed limbs.
The device applies a steady increasing force, starting and stopping using the foot pedal. No calibration required. Digital model with force sensors and electronic unit is also...
For stereotaxic surgery using rats or other small animals. Can be used to locate targets for implantation of devices, stimulation or injections.
Smooth, consistent movements with rapid positioning. Time-proven 'U'-Frame design provides stability and adaptability. Integrated warming base can be activated for better surgical outcomes.
The KDS Legato series is a range of advanced, precision syringe pumps. For applications requiring high metering precision at low, pulse-free flow rates.
Intuitive touch screen allows user to easily define complex injection protocols. Display presents real time data.
Provides precise information on the optimum day for mating during estrous cycle in the rats.
A powerful tool for improving reproduction efficiency. Simple, quick operation. Automatically calibrated when turned on. Designed for rats. A probe is available for mice.
Used to measure the paw withdrawal reflex when the mouse or rat paw is unexpectedly touched. For evaluating mechanical allodynia and cutaneous sensation levels. Popular non-invasive technique.
Aesthesio® set of 20 monofilaments based on the Semmes Weinstein monofilament set. An ascending series of increasingly stiff filaments (from 0.008 to 300 grams). Features retractable head to...
The Durham Holders are new rat holders for trigeminal stimulation, the newest accessory for use with the Plantar Test and Dynamic Plantar Aesthesiometer, manufactured by Ugo Basile.