  • Animal
    Mouse, Rat

    Enables recording of spontaneous locomotor activity in rats and mice (individual or groups) using infrared (I.R.) beams. General activity can be an indicator of drug action, toxic substances, neurological damage, or daily rhythms in activity.

    Tracks horizontal and vertical activity (rearing). Easily integrated with video-tracking system to measure XY position. Easy touch-buttons,...

    Animal
    Mouse, Rat

    Measures the force on a rat or mouse paw according to the Randall-Selitto paw-pressure test, it enables rapid and precise screening of analgesic drugs for anti-nociceptive studies, in healthy or inflamed limbs. The device applies a steady increasing force, starting and stopping using the foot pedal. No calibration required. Digital model with force sensors and electronic unit is also...

    Animal
    Mouse, Rat
    Blood Pressure Recorder-Non Invasive, shown with a mouse in its holder and the pressure generator (proximal) and the piezo sensor (distal)

    A multi-function, non-invasive blood pressure recorder for small to medium animals (mice to dogs) for use in a wide range of scientific studies, where systolic and diastolic pressure needs to be measured in a non-invasive way in anesthetized or awake animals.

    Combines functionality of multiple systems including pressure generation-pressure monitoring system, pulse amplifier,...

  • Animal
    Mouse, Rat

    Invasive arterial or venous blood pressure measurement during animal surgery. For urodynamic, intrauterine and intracranial studies. Also suitable for intensive care.

    Connects to data acquisition systems such as our DataCapsule-Evo. High quality, robust, reusable and cost effective.

    Animal
    Mouse, Rat

    Evaluates the spasm-inducing effect of drugs. Typically assesses the effect of bronchodilation agents. Also used for screening substances inducing opposite effects.

    Simple, reliable and fast method to assess airflow resistance. High precision recording of volume. Available as a complete set up with a rodent ventilator and data acquisition system.

    Animal
    Other

    A positive pressure pump (according to Starling's Ventilator method) for cats, rabbits and small animals of similar size. Assists with breathing during anesthesia and surgery or when an animal has an injury or illness that requires respiratory support.

    Highly accurate rate displayed digitally, choice of cylinder/piston assemblies (50, 100 ml), quiet, robust, high quality, and long...

  • Animal
    Mouse
    Climbing Test front view. he system is composed of 4 channel electronic unit, climbing cylinder and ceiling

    Climbing behavior can be of interest for the most diverse applications.

    The Ugo Basile automated system replicates its first manual application in the Pain field, for measuring Pain-Depressed behavior. It showed that, while mild analgesics block pain-depressed climbing, strong analgesics fail to alleviate depression of climbing (Santos et al. 2023, “Climbing behavior by mice as an...

    Animal
    Mouse, Rat

    Provides and easy to use means of immobilizing an animal for surgery or procedures such as imaging. Gas Anesthesia (compared to injections) is a very quick way to induce total unconsciousness and also assists fast recovery.

    High quality compact, modular and virtually unbreakable system. Reliable and precise delivery of the anesthetic gas to animals. Expandable system providing...

    Animal
    Other

    Provides accurate recording of isometric or isotonic tissue contraction/release. For studying effects of drugs or electrical stimuli on isolated smooth muscles (including uterus, trachea, gastrointestinal tract, vessel strips, auricle etc) under optimum conditions.

    Classic pharmacology tool for research and teaching. Maintains the integrity of live muscle tissue for several hours in...

  • Electric Schock Meter

    An essential instrument to measure current on Ugo Basile devices using electric shock grid, such the Fear Conditioning System, Active an Passive avoidance system.

    Give the research the ability to measure the electric shock current not measurable by a common volt-meter. To ensure that the same current is delivered on multiple electric shock grids, while performing multiple test in...

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The elevated plus maze (EPM) is used to measure anxiety in rats and mice. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.

    High quality maze with surface texture selected for best rodent comfort. Optimized for use with video tracking software (high...

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The Elevated Zero-Maze is an alternative model to the Elevated Plus Maze (EPM). Its circular design provides a smoother transition from closed to open space. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.

    High quality maze with surface texture selected...

  • Animal
    Mouse, Rat
    Fear Conditioning System. Cubicle front view with door open and animal cage with checkerboard contexts mounted

    The Ugo Basile Fear Conditioning system is composed of:

    • Isolation cubicle, including all electronics, fan, IR/VIS lights, camera (up to 16 cubicles can be connected to 1 PC)
    • The animal cage is available in different dimensions for rats and mice, plus the observational learning version to allow two animals to see each other. The standard...
    Animal
    Mouse, Rat

    The Grip Strength Meter determines the maximum force displayed by an animal in the forelimb, hind-limb or all four limbs, thanks to the full set of accessories included in the Ugo Basile Grip Strength Meter package.

    The technique exploits the instinctive resistance of rodents to backward movements and their consequence tendency to grasp (grip) against the pull-back...

    Animal
    Mouse, Rat

    Studies natural curiosity and exploration behavior of rodents when confronted with a new environment (head-plunging, or nose-poking stereotype) according to the method devised by Boissier-Simon. For testing effects of psychotropic drugs on exploratory behavior.

    The Boards are available with opaque or transparent walls for use with video tracking software. Mouse or rat versions.

  • Animal
    Mouse, Rat
    Hot/Cold Plate - Screening of Thermal Hyperalgesia/Allodynia

    The hot cold plate test has been the gold standard test for thermal pain tests in rodents for decades. Through the years the devices have been improving and the techniques have become more sophisticated, adding to constant temperature methods also other ones.

    The Ugo Basile Hot/Cold plate test includes all the latest technologies necessary to run constant temperature, linear ramping...

    Animal
    Mouse, Rat

    Provides simple, reliable and precise calibration for Ugo Basile Plantar Test & Tail Flick and other infrared (I.R.) analgesia meters.

    Animal
    Mouse, Rat
    Librae Incapacitance tester with Rat restrainer. Notice the foot pedal in case the experimenter wants to start/stop the test manually

    Measures the weight distribution difference between an injured and unaffected hind paw of a mouse or rat. For the assessment of spontaneous pain in osteoarthritis, bone cancer, nerve injury and post-operative pain studies. Automatic operation reduces operator bias, optimizes repeatability and saves time. Easy to set up. Data visualization to monitor trends. Fast and easy cleaning...

  • Animal
    Mouse, Rat, Other

    Convenient, cost-effective solution to confine rodents and small animals for anesthesia procedures.

    Models available in 2 sizes – smaller model for rodents and larger model for rabbits and similarly sized animals. Clear Perspex with a sliding lid. Quick connection to anesthesia or euthanasia systems using the 2 tubing connectors.

    Animal
    Other

    Provides accurate recording of isometric or isotonic tissue contraction/release. For studying effects of drugs or electrical stimuli on isolated smooth muscles (including uterus, trachea, gastrointestinal tract, vessel strips, auricle etc) under optimum conditions.

    Classic pharmacology tool for research and teaching. Maintains the integrity of live muscle tissue for several hours in...

    Animal
    Other

    Measures the force (or tension) of isolated tissue when its length is constant. Pharmacological responses can be characterized by the contractile/relaxant properties.

    Four models available covering range from 0 to 50g. Highest-sensitivity model covers the range 0-800mg. Sturdy construction. Connects to popular data acquisition systems.

  • Animal
    Other

    For investigating isotonic contractions (changes in tissue length) of isolated muscles and measuring small displacements in physiological preparations. Typically used to study the contractile/relaxation effects of drugs.

    Perfect for studies using extremely small and fast muscle fibers. Set up a comprehensive system by adding our data acquisition system, organ baths, electrodes and...

    Animal
    Mouse, Rat

    The KDS Legato series is a range of advanced, precision syringe pumps. For applications requiring high metering precision at low, pulse-free flow rates.

    Intuitive touch screen allows user to easily define complex injection protocols. Display presents real time data.

    Animal
    Mouse, Rat

    Compact, direct current (DC) Lesion Maker for localized electrolytic lesions in the brain.

    Isolated, regulated DC output for electrical safety. Two operating modes: Continuous and Timed.

  • Animal
    Mouse

    A positive pressure pump (according to Starling's Ventilator method) for mice. Assists with breathing during anesthesia and surgery or when an animal has an injury or illness that requires respiratory support.

    Highly accurate, rate displayed digitally, quiet, durable, high quality, long lifetime. Up to 300 strokes/min. Optimizes oxygenation by minimizing dead space. Range of...

    Animal
    Mouse, Rat

    Patented non-invasive vital signs monitor. Measures heart rate, arterial oxygen saturation (SpO2), breath rate, and temperature (optional) of anesthetized and conscious small laboratory animals of various sizes.

    Clinically validated and cited in a range of published studies including respiratory, neonatal, hypertension and brain injury.

    Animal
    Mouse
    Videotracking
    Traditional

    Automatically scores wheel rotations, corresponding to rodent escape behaviors. A primary screening test for antidepressants.

    Automates up to 40 tests simultaneously for high throughput. Durable, easy to assemble. Optimized for use with video tracking software.

  • Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The Open Field is used to assess exploratory behavior. Validated for use in the measurement of anxiety related behaviors. Also suited to the novel object recognition (NOR) test.

    Decreased anxiety leads to increased exploratory behavior. Increased anxiety results in less locomotor motion and preference for the edges of the field.

    Animal
    Mouse
    Videotracking
    Traditional, Infrared
    Operant Fear Conditiong Cage in a Fear Conditioning Isolation Cubicle, view of the operant wall

    The Operant Fear Conditioning Cage couples a classic skinner box with sound and light cues for complex experiments, as well as standard operant tests and fear conditioning protocols.

    Animal
    Rat

    Measures hypersensitivity to thermal (hot and cold) and/or mechanical stimulation of the orofacial area in rats (mouse adaptor available). For research into a wide range of pain conditions involving the trigeminal nerve.

    High throughput with data recorded from up to 16 cages with ORO-Software. Real time data display. Non-invasive, respectful test. Comprehensive metrics and easy data...