Standard Anesthesia Systems for Isoflurane
|
21100
|
Single-Output Anesthesia System, including Basic Single-Output Anesthesia System, scavenger (Activated Charcoal Canister), evac tubing
|
21200
|
Double-Output Anesthesia System, including 21050, scavenger (Activated Charcoal Canister), evac tubing and dual diverter manifold, for simultaneous connection of nose-cone/mask and induction box
|
Delivery Systems (Masks & Induction Boxes)
|
select from the following accessories, according to your experimental needs and to your animal model: |
PS-0525-A
|
Nose-Cone/Mask for Small Mice, with diaphragm and Inlet Adaptor
|
PS-0305-A
|
Nose-Cone/Mask for Large Mice, as above, 3cm diam
|
PS-0306-A
|
Nose-Cone/Mask for Small Rats, as above, 3,8cm diam
|
PS-0307-A
|
Nose-Cone/Mask for Medium Rats, as above, 5cm diam.
|
PS-0308-A
|
Nose-Cone/Mask for Large Rats, as above, 5.5cm diam.
|
7900
|
Induction Box for small rodents (mice and rats), 25x13x13 (h) cm
|
7910
|
Induction Box, large size, 40x22x21 (h) cm
|
21100-790
|
Induction Box for small rodents (mice and rats) 25x13x13(h) cm
|
Multiple-Output Delivery Systems
|
PS-0529-02
|
Dual Diverter Manifold with humidifier (see also 21200)
|
PS 30-456
|
Multiple-Animal Delivery System, with 2 Flowmeters
|
PS 30-457
|
Multiple-Animal Delivery System, with 3 Flowmeters
|
PS 30-458
|
Multiple-Animal Delivery System, with 4 Flowmeters
|
PS 30-460
|
Multiple-Animal Delivery System, with 5 Flowmeters
|
PS 30-459
|
Multiple-Animal Delivery System, with 6 Flowmeters
|
Anesthetic Scavenger and Evacuation
|
PS-0581-00
|
F/air filter (activated charcoal canister)
|
PS-0581-01
|
F/air filter (activated charcoal canister), pkg. of 8
|
21100-833
|
Active Scavenger, to remove the anesthetic agent by applying negative pressure (can also be connected to an activated charcoal canister)
|
Heating Pads
|
21100-800M
|
Rodent Warmer with 21100-810 Mouse Heating Pad
|
21100-800R
|
Rodent Warmer with 21100-812 Rat Heating Pad
|
21100-800C
|
Rodent Warmer with 21100-814 Cage Heating Pad
|
21100-304
|
Rectal Thermal Probe
|
PS-0811
|
Delta-Phase Iso-therm Heating Pads (pkg of 3), 20x20x0,65cm. Maintains animal body temperature near 37°C up to several hours. Ideal for NMR
|
Other Accessories
|
PS-09
|
Fill Device for Isoflurane
|
PS-0949
|
Fill Device for Halothane
|
PS-0951
|
Fill Device for Sevoflurane
|
SPECIAL SYSTEMS WITH N2O
|
22100
|
O2/N2O Anesthesia System, complete with 2 Analog Flowmeters, TEC-3 vaporizer for Isoflurane (vaporizers for other anesthetic agents are available on request), scavenger (Activated Charcoal Canister), tubing.
|
TO COMPLETE YOUR EQUIPMENT
|
We also offer a complete line of Ventilators, which includes models for Mouse, Rats, Cat/Rabbit: |
28025
|
Mouse Ventilator, complete with 1ml or 0.5ml (model 28025-5) cylinder/piston assembly & standard accessories. Universal input 85-264 VAC, 50-60Hz
|
28025-150
|
Connection Kit for Anesthesia System to Ventilator 28025
|
7025
|
Rodent Ventilator, complete with 10ml, 30ml (7025-30) or 5ml (7025-5) cylinder/piston assembly and standard accessories. Universal input 85-264 VAC, 50-60Hz
|
7025-150
|
Connection Kit for Anesthesia System to Ventilator 7025
|
6025
|
Cat/Rabbit Ventilator, complete with 50ml or 100ml (6025-100) cylinder/piston assembly and standard accessories. Universal input 85-264 VAC, 50-60Hz
|
6025-150
|
Connection Kit for Anesthesia System to Ventilator 6025
|
All ventilators are available with suitable circuit & BNC connector for synchronized START/STOP.
|