Quote list0
Your product list is empty!
Results 1 - 20 of 20
Show per page
  • Animal
    Mouse, Rat
    Videotracking
    Traditional

    Versatile, automated modular device empowers researchers to assemble a custom configuration perfectly suited to spatial learning and spatial memory studies in rats or mice.

    The same modular device can be transformed into automated radial, Y, T and Delta mazes by simply rearranging the arms.

    Surface texture is selected for best rodent comfort as well as optimal results with...

    Animal
    Mouse, Rat

    This software enables researchers to study behavior in a more reliable and consistent way and over longer time periods than if they were using direct observation or manual recording.

    Highly advanced, comprehensive video-tracking system. The software couples an unrivalled depth of features with a simple, familiar design, to provide automated testing in virtually any behavioral...

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    To perform Light/Dark Test with rats or mice for assessing anxiety. Useful in identifying and/or screening of anxiolytic and anxiogenic agents.

    High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent comfort. Easy to set up, easy to clean.

  • Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The Radial Arm Maze has 8 equally spaced arms radiating from a central circular compartment. It can be used for several sophisticated protocols to study spatial, working and reference learning and memory.

    The animal can rely on egocentric or allocentric strategies. Working versus reference memory can be assessed by adopting intra or inter trial protocols. Easy to set up, easy to...

    Animal
    Mouse, Rat
    Videotracking
    Traditional

    The Barnes Maze is a valid alternative to the water maze to study spatial learning and memory. The motivational drive is the rodent’s instinctive aversion for open spaces and natural preference for dark, “sheltered” spaces.

    Reliable and durable. Optimized for use with video-tracking software. Available for mice or rats. Easy to set up, easy to clean.

    Animal
    Mouse, Rat
    Videotracking
    Traditional

    Atlantis System allows platforms in a Morris Water Maze to rise gently to near the surface or go down automatically, using the manual controller or TTL signals. From one to four platform systems available.

    Enables extinction protocols on rats or mice. No need to stop the test to manually remove or reposition platforms.

  • Animal
    Mouse, Rat
    Videotracking
    Traditional

    A test for spatial learning and long-term memory in rodents. For research into neurocognitive disorders and treatments, aging, drug-abuse, neural systems, neurotransmitters and brain development.

    High quality, strong and low weight. Embedded wheels for easy movement. Easy to drain and clean. Add optional Atlantis System to extend test capabilities. Different colors available.

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    Widely used to measure preference and spatial memory and learning tasks in laboratory animals. The simple T-shape design provides a single choice point with only two alternatives. Especially for CNS disorder studies.

    High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent...

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    A simple Y-shape design provides rodents with a single choice point with only two alternatives. Widely used to measure preference and spatial memory and learning tasks in laboratory animals.

    High quality maze with rat and mouse versions. Provides optimal results with video tracking software (high contrast, non reflective). Surface texture selected for rodent comfort. Easy to set up,...

  • Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The Open Field is used to assess exploratory behavior. Validated for use in the measurement of anxiety related behaviors. Also suited to the novel object recognition (NOR) test.

    Decreased anxiety leads to increased exploratory behavior. Increased anxiety results in less locomotor motion and preference for the edges of the field.

    Animal
    Mouse, Rat
    Fear Conditioning System. Cubicle front view with door open and animal cage with checkerboard contexts mounted

    The Ugo Basile Fear Conditioning system is composed of:

    • Isolation cubicle, including all electronics, fan, IR/VIS lights, camera (up to 16 cubicles can be connected to 1 PC)
    • The animal cage is available in different dimensions for rats and mice, plus the observational learning version to allow two animals to see each other. The standard...
    Electric Schock Meter

    An essential instrument to measure current on Ugo Basile devices using electric shock grid, such the Fear Conditioning System, Active an Passive avoidance system.

    Give the research the ability to measure the electric shock current not measurable by a common volt-meter. To ensure that the same current is delivered on multiple electric shock grids, while performing multiple test in...

  • Animal
    Mouse, Rat
    Load Cell and restrainer with embedded speaker and air puff for stimulation and startle/PPI detection

    Pre-pulse inhibition of the Startle reflex (PPI) is a phenomenon in which a weak stimulus (sound or light, or air-puff) suppress the startle response to a subsequent stronger startle stimulus (of the same kind).

    The interest in this technique is mainly due to the fact that impairment in PPI is normally linked to a dysfunction in the sensorimotor mechanism, which has been shown in...

    Animal
    Mouse, Rat

    A set up for testing active avoidance (also called automatic reflex conditioner or shuttle box), i.e. learning to predict the occurrence of an aversive event, based on the presentation of a specific stimulus. Enables performance of a wide range of avoidance experiments using a flexible schedule. Precise detection of avoiding aversive event. Manage up to 4 cages with one controller.

    Animal
    Mouse, Rat

    The cubicle is a sound-attenuating chamber that isolates small animal subjects from distracting ambient light, sound and activity. For behavioral studies including operant behavior (Skinner), self-administration, etc.

    High-level soundproof efficacy, noiseless fan, control box. Extra fixtures (speaker and video camera holder) for fear conditioning studies. Available in standard, large...

  • Animal
    Mouse, Rat

    Passive Avoidance Test is used to assess memory function based on the association formed between a specific environmental context, which the animal learns to avoid and an aversive stimulus – represented by a mild foot shock.

    Efficient and reliable. Silent, automated sliding door divides the dark and light compartments. Systems for mice or rats. Manage up to 4 cages with one...

    Animal
    Mouse, Rat

    When rodents are exposed to inescapable and unpredictable stress, such as forced swim or inescapable foot shock, they often develop deficits in memory and learning tasks (e.g. Active Avoidance) and they often show analgesic reactions (S.I.A. Stress-Induced Analgesia).

    The Ugo Basile Set-Up for Learned Helplessness is based on a sophisticated generator of unpredictable random shocks...

    Animal
    Mouse
    Videotracking
    Traditional, Infrared
    Operant Fear Conditiong Cage in a Fear Conditioning Isolation Cubicle, view of the operant wall

    The Operant Fear Conditioning Cage couples a classic skinner box with sound and light cues for complex experiments, as well as standard operant tests and fear conditioning protocols.

  • Animal
    Mouse, Rat
    Animal
    Rat
    Cincinnati Water Maze for rats, view from above

    The Cincinnati Maze (9T-maze) is an evolution of the Biel Maze with an increased number of interconnected T-mazes.

    It is most commonly used as a water maze to avoid scent issues and is used on rats to study egocentric navigation (memory). In order to avoid any possibility of external cue use, the maze is constructed in IR-transparent Perspex to run the experiment in full darkness and...

Filters