Quote list0
Your product list is empty!
Results 31 - 47 of 47
Show per page
  • Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The elevated plus maze (EPM) is used to measure anxiety in rats and mice. The model is based on the rodent's instinctive tendency to explore novel environments and also to avoid unprotected open and elevated spaces. For neurobiological anxiety research.

    High quality maze with surface texture selected for best rodent comfort. Optimized for use with video tracking software (high...

    Animal
    Mouse, Rat
    Videotracking
    Traditional, Infrared

    The Open Field is used to assess exploratory behavior. Validated for use in the measurement of anxiety related behaviors. Also suited to the novel object recognition (NOR) test.

    Decreased anxiety leads to increased exploratory behavior. Increased anxiety results in less locomotor motion and preference for the edges of the field.

    Animal
    Mouse, Rat

    A warmer to provide external heat to animals undergoing surgery. Helps to maintain near-normal body temperature for improved surgical outcomes (such as fewer adverse cardiac events and reduced blood loss).

    Preprogrammed animal temperatures, easy-to-use control, lightweight with small footprint. Select Rodent Warmer X2 for simultaneous control of 2 independent heating pads.

  • Animal
    Mouse, Rat

    Evaluates the spasm-inducing effect of drugs. Typically assesses the effect of bronchodilation agents. Also used for screening substances inducing opposite effects.

    Simple, reliable and fast method to assess airflow resistance. High precision recording of volume. Available as a complete set up with a rodent ventilator and data acquisition system.

    Animal
    Mouse
    Videotracking
    Traditional

    Automatically scores wheel rotations, corresponding to rodent escape behaviors. A primary screening test for antidepressants.

    Automates up to 40 tests simultaneously for high throughput. Durable, easy to assemble. Optimized for use with video tracking software.

    Animal
    Mouse, Rat, Other

    Convenient, cost-effective solution to confine rodents and small animals for anesthesia procedures.

    Models available in 2 sizes – smaller model for rodents and larger model for rabbits and similarly sized animals. Clear Perspex with a sliding lid. Quick connection to anesthesia or euthanasia systems using the 2 tubing connectors.

  • Animal
    Mouse, Rat
    Hot/Cold Plate - Screening of Thermal Hyperalgesia/Allodynia

    The hot cold plate test has been the gold standard test for thermal pain tests in rodents for decades. Through the years the devices have been improving and the techniques have become more sophisticated, adding to constant temperature methods also other ones.

    The Ugo Basile Hot/Cold plate test includes all the latest technologies necessary to run constant temperature, linear ramping...

    Animal
    Mouse, Rat
    Fear Conditioning System. Cubicle front view with door open and animal cage with checkerboard contexts mounted

    The Ugo Basile Fear Conditioning system is composed of:

    • Isolation cubicle, including all electronics, fan, IR/VIS lights, camera (up to 16 cubicles can be connected to 1 PC)
    • The animal cage is available in different dimensions for rats and mice, plus the observational learning version to allow two animals to see each other. The standard...
    Electric Schock Meter

    An essential instrument to measure current on Ugo Basile devices using electric shock grid, such the Fear Conditioning System, Active an Passive avoidance system.

    Give the research the ability to measure the electric shock current not measurable by a common volt-meter. To ensure that the same current is delivered on multiple electric shock grids, while performing multiple test in...

  • Animal
    Mouse, Rat
    Load Cell and restrainer with embedded speaker and air puff for stimulation and startle/PPI detection

    Pre-pulse inhibition of the Startle reflex (PPI) is a phenomenon in which a weak stimulus (sound or light, or air-puff) suppress the startle response to a subsequent stronger startle stimulus (of the same kind).

    The interest in this technique is mainly due to the fact that impairment in PPI is normally linked to a dysfunction in the sensorimotor mechanism, which has been shown in...

    Animal
    Mouse, Rat

    A set up for testing active avoidance (also called automatic reflex conditioner or shuttle box), i.e. learning to predict the occurrence of an aversive event, based on the presentation of a specific stimulus. Enables performance of a wide range of avoidance experiments using a flexible schedule. Precise detection of avoiding aversive event. Manage up to 4 cages with one controller.

    Animal
    Mouse, Rat

    The cubicle is a sound-attenuating chamber that isolates small animal subjects from distracting ambient light, sound and activity. For behavioral studies including operant behavior (Skinner), self-administration, etc.

    High-level soundproof efficacy, noiseless fan, control box. Extra fixtures (speaker and video camera holder) for fear conditioning studies. Available in standard, large...

  • Animal
    Mouse, Rat

    Passive Avoidance Test is used to assess memory function based on the association formed between a specific environmental context, which the animal learns to avoid and an aversive stimulus – represented by a mild foot shock.

    Efficient and reliable. Silent, automated sliding door divides the dark and light compartments. Systems for mice or rats. Manage up to 4 cages with one...

    Animal
    Mouse, Rat

    When rodents are exposed to inescapable and unpredictable stress, such as forced swim or inescapable foot shock, they often develop deficits in memory and learning tasks (e.g. Active Avoidance) and they often show analgesic reactions (S.I.A. Stress-Induced Analgesia).

    The Ugo Basile Set-Up for Learned Helplessness is based on a sophisticated generator of unpredictable random shocks...

    Animal
    Mouse
    Videotracking
    Traditional, Infrared
    Operant Fear Conditiong Cage in a Fear Conditioning Isolation Cubicle, view of the operant wall

    The Operant Fear Conditioning Cage couples a classic skinner box with sound and light cues for complex experiments, as well as standard operant tests and fear conditioning protocols.

  • Animal
    Mouse
    TGR Thermal Gradient Ring 2.0

    The TGR can clearly discriminates temperature-dependent phenotypes or temperature dependent drug effects.

    It records and analyses thermal preference/avoidance in mice. For neuropathic pain studies, peripheral neuropathy, temperature sensitivity and insensitivity assessment in basic research, phenotyping and drug screening.

    The animal is freely moving, its position is tracked by...

    Animal
    Rat
    Cincinnati Water Maze for rats, view from above

    The Cincinnati Maze (9T-maze) is an evolution of the Biel Maze with an increased number of interconnected T-mazes.

    It is most commonly used as a water maze to avoid scent issues and is used on rats to study egocentric navigation (memory). In order to avoid any possibility of external cue use, the maze is constructed in IR-transparent Perspex to run the experiment in full darkness and...

Filters