Quote list0
Your product list is empty!

Animal
Mouse, Rat

Plethysmometer - Paw Volume & Oedema

Product Code:37240/37240-25/37240-35

Measures small changes in volume & oedema (fluid retention) to gauge the inflammatory response such as for anti-inflammatory screening tests.

Hands-free operation. Precision measurements. Detects and displays 0.01 ml changes in rodent paw volume. Easy data transfer and software included.

Model
Choose a model to get a quote...
An extended warranty can be added for most Ugo Basile products. You can find this information in the ordering information section of each product.
To learn more about the extended warranty, CLICK HERE

Background

  • The new original device by Ugo Basile designed to measure paw volume and its changes (swelling) in rodents.
  • Used to precisely measure experimentally induced inflammation and changes due to administration of pharmacological substances.
  • New version with touch screen display, new firmware with more functions, with USB data retrival and experiment data loading capabilities, LAN connection, auto-mesure function and Ugo Basile family feeling design.
  • Over 3000 citations of Ugo Basile’s Plethysmometer in scientific publications.

Precise measurements, hands free operation

  • Displays the exact paw volume on the touch screen display, read-out with resolution of 0.01ml. Small differences are detected by an high precision self-made level transducer
  • Foot pedal that allows hands-free operation, to saved measured value and to enable auto-measure function
  • Easy zeroing before making new measurements.
  • Measuring paw tubes available in different sizes for different animals paws
  • Web-based LAN connection for data retrieving and experiment data loading (password protected)
  • USB pen drive for data retrieving and experiment data loading

 

 

Feature

Benefits

Touch screen display Easy to operate, easily result data viewing
Auto-measure function Easy operation and better measuring accuracy and repeatability
USB pen drive For fast measured data retrieving and experiment data loading
Web based LAN connection Remote data retrieving and experiment data loading
Foot-Pedal to freeze the reading Hand-free operation
More than 1000 citations since 1960s Most applications can be found in bibliography for reference
Interchangeable water cells Same instrument for mice and rats (four different dimensions)

Operation

Power Requirement Universal input 85-264 VAC, 50-60Hz, 15 W max
Data Read-out Multifunction graphic display
Display 4.3” multifunction color touch-screen display
Data Format  4 digits 2 integers, 2 decimals (e.g.:23.89 ml)

 

Physical

Weight 3,5 Kg
Shipping Weight 6.5 Kg
Shipping Dimension 36x55x45 cm

 

Warranty

Warranty Plethysmometer is covered by a 12-month warranty + 12 after product registration
UB Care Additional UB-Care can be added for other 12 or 24 months

The Plethysmometer is an instrument designed to measure very small changes in volume via water displacement measured by a special very precise in house made transducer.

The availability of different (4) paw measurement tubes makes the device adaptable to many different paw dimensions.

In the 60s, Ugo Basile developed the first original device, designed specifically to measure paw swelling in rodents, since then, thousands of scientists have relied on our Plethysmometer to conduct their research on inflammation, publishing almost 3.000 scientific papers! 

The instrument is typically used to precisely measure the experimentally induced inflammation of the paw in rodents and its changes due to administration of pharmacological substances potentially active on inflammation.

37240 Plethysmometer Standard Package (What's in the box)

37240-210 Plethysmometer cell stand
37240-154 Water Tank
37240-001 Plethysmometer electronic unit
37252 Standard water cell with Mouse paw tube (diam. 13 mm) and Rat paw tube (diam. 18 mm) with Water level transducer
7155 Set of Calibration Probes (0.1, 0.2, 0.5, 1, 2, 4 ml)
7160 Wetting Compound, 100ml bottle
M-TF 050-F 2 mt. of Polyurethane tube for connection: cell to water tank & cell to drain
7168 Cell Simulator for end-user troubleshooting
E-AU 101 USB Pen Drive including instruction manual (with CE certification), and X-Pad software
37215-303 Pedal Switch 

37240-25 Plethysmometer with special water cell with Rat paw tube (25 mm) (What's in the box)

37240-210 Plethysmometer cell stand
37240-154 Water Tank
37240-001 Plethysmometer electronic unit
37257 Special water cell with Rat paw tube (diam. 25 mm) with Water level transducer
7155 Set of Calibration Probes (0.1, 0.2, 0.5, 1, 2, 4 ml)
7160 Wetting Compound, 100ml bottle
M-TF 050-F 2 mt. of Polyurethane tube for connection: cell to water tank & cell to drain
7168 Cell Simulator for end-user troubleshooting
E-AU 101 USB Pen Drive including instruction manual (with CE certification), and X-Pad software
37215-303 Pedal Switch 

37240-35 Plethysmometer with special water cell with Rat paw tube (35 mm) (What's in the box)

37240-210 Plethysmometer cell stand
37240-154 Water Tank
37240-001 Plethysmometer electronic unit
37259 Special water cell with Rat paw tube (diam. 35 mm) with Water level transducer
7155 Set of Calibration Probes (0.1, 0.2, 0.5, 1, 2, 4 ml)
7160 Wetting Compound, 100ml bottle
M-TF 050-F 2 mt. of Polyurethane tube for connection: cell to water tank & cell to drain
7168 Cell Simulator for end-user troubleshooting
E-AU 101 USB Pen Drive including instruction manual (with CE certification), and X-Pad software
37215-303 Pedal Switch 

Other Avaible Water Cells And Accessories

37252 Standard water cell with Mouse paw tube (diam. 13 mm) and Rat paw tube (diam. 18 mm) with water level transducer
37252-S Standard water cell with Mouse paw tube (diam. 13 mm) and Rat paw tube (diam. 18 mm) without water level transducer
37257 Special water cell with Rat paw tube (diam. 25 mm) with water level transducer
37257-S Special water cell with Rat paw tube (diam. 25 mm) without water level transducer
37259 Special water cell with Rat paw tube (diam. 35 mm) with water level transducer
37259-S Special water cell with Rat paw tube (diam. 35 mm) without water level transducer
7182 18 mm Displacement Tube for the rat paw
7186 13 mm Displacement Tube for the mouse paw
7187 25 mm Displacement Tube for the rat paw
7189 35 mm Displacement Tube for the rat paw
7153-L Water level transducer
Optional Warranty
37240-UBC12 UB Care 12 Additional hardware warranty extension 12 months for Plethysmometer (Valid for SKU 37240)
37240-UBC24 UB Care 24 Additional hardware warranty extension 24 months for Plethysmometer (Valid for SKU 37240)
37240-25-UBC12 UB Care 12 Additional hardware warranty extension 12 months for Plethysmometer (Valid for SKU 37240-25)
37240-25-UBC24 UB Care 24 Additional hardware warranty extension 24 months for Plethysmometer (Valid for SKU 37240-25)
37240-35-UBC12 UB Care 12 Additional hardware warranty extension 12 months for Plethysmometer (Valid for SKU 37240-35)
37240-35-UBC24 UB Care 24 Additional hardware warranty extension 24 months for Plethysmometer (Valid for SKU 37240-35)

A. M. Ajayi, C. B. Ola, M. B. Ezeagu, P. A. Adeleke, K. A. John, M. O. Ologe, B. Ben-Azu, S. Umukoro, 2023, “Chemical characterization, anti-nociceptive and anti-inflammatory activities of Plukenetia conophora seed oil in experimental rodent models”, Journal of Ethnopharmacology

D. Impellizzeri, D. Maftei, C. Severini, R.Miele, G. Balboni, R. Siracusa, M. Cordaro, R. Di Paola, S. Cuzzocrea, R. Lattanzi, 2023, “Blocking prokineticin receptors attenuates synovitis and joint destruction in collagen-induced arthritis”, Journal of Molecular Medicine

O. O. Ariyo, A. M. Ajayi, B. Ben-Azu, A. O. Aderibigbe, 2022, “Morus mesozygia leaf extract ameliorates behavioral deficits, oxidative stress and inflammation in Complete Freund’s adjuvant-induced arthritis in rats”, Journal of Ethnopharmacology

A. Bucan, A. Wiinholt, F. Dalaei, O. Gerke, C. Ronn Hansen, J. Ahm Sorensen, 2022, “Microcomputed tomography versus plethysmometer and electronic caliper in the measurements of lymphedema in the hindlimb of mice”, Scientific Reports

Y. Fotio, O. Sasso, R. Ciccocioppo, D. Piomelli, 2021, “Antinociceptive Profile of ARN19702, (2-*thylsulfonylpheny*)-[(2S)-4-(6-fluor*-1,3-*enzothiazo*-2-yl)-2-*ethylpiperazi*-1-yl]*ethanon*, a Novel Orally Active N-*cylethanolamin* Aci* Amidas* Inhibitor, in Animal Models”, Journal of Pharmacology and Experimental Therapeutics

T. Keränen, T. Hömmö, M. Hämäläinen, E. Moilanen, R. Korhonen, 2026 “Anti-Inflammatory Effects of β2-Receptor Agonists *albutamo* and *erbutalin* Are Mediated by MKP-1”, PLoS ONE

A. Horvat, v. Tékus, M. Boros, G. Pozsgai, B. Potz, E. Borbély, J. Szolcsanyi, E. Pinter, Z. Helyes, 2016, “Transient Receptor Potential Ankyrin 1 (TRPA1) Re-ceptor is Involved in Chronic Arthritis: in Vivo Study Using TRPA1-Deficient Mice”, Arthritis research & therapy

F. T. Bonezzi, O. Sasso, S. Pontis, N. Realini, E. Romeo, S. Ponzano, A. Nuzzi, A. Fiasella, F. Bertozzi and D. Piomelli, 2016, “An Important role for N-*cylethanolamin* Aci* Amidas* in the Complete Freund’s Adjuvant Rat Model of Arthritis”, Journal of Pharmacology and Experimental Therapeutics

T. Iannitti, A. Graham, S. Dolan, 2015, “Adiponecti*-Mediated Analgesia and Anti-Inflammatory Effects in Rat” PLoS ONE

Back to: Pain and Inflammation

Research insights

Preclinical research in pain and inflammation

Pain affects an estimated 20% of adults worldwide, with millions of new chronic pain cases diagnosed every year. Yet, it remains insufficiently addressed as a major public health issue. Recognizing pain as a complex condition influenced by biological, social and environmental factors is essential to improve research, prevention, treatment and health policies.

Developing safer and more effective pain management strategies requires a deeper understanding of the biological mechanisms underlying pain and inflammation. In this context, preclinical research plays a fundamental role in identifying therapeutic targets, evaluating novel treatments and generating evidence to support translation into clinical practice.

Most used paradigms for pain and inflammation research

Pain and inflammation research uses a combination of evoked and spontaneous paradigms to assess nociception, hypersensitivity, inflammatory responses and pain-related impairment in rodents. Evoked thermal paradigms include plantar stimulation, tail flick, hot/cold plate testing, thermal place preference and thermal gradient assessment, which are used to investigate heat sensitivity, cold sensitivity, thermal hyperalgesia, allodinya and thermal preference or avoidance.

Mechanical paradigms include dynamic plantar stimulation, electronic or manual Von Frey testing, paw pressure testing and direct joint pressure application, supporting the assessment of mechanical allodynia, hyperalgesia and joint hypersensitivity. Spontaneous pain paradigms include weight-bearing asymmetry, postural imbalance, vertical activity and gait or locomotor changes, which are particularly relevant in arthritis, neuropathic pain, bone cancer pain, post-surgical pain and inflammatory models.

Inflammation can also be evaluated as a dedicated endpoint through paw volume and oedema measurement, allowing researchers to quantify experimentally induced swelling and pharmacological treatment effects.

Specific pain conditions like the ones involving the Trigeminal nerve are assessed by dedicated devices for thermal and mechanical stimulation of the animal vibrissae area, during the Orofacial Test.

Key behavioral readouts in pain assessment

Pain and inflammation studies rely on behavioural readouts that quantify nociceptive thresholds, hypersensitivity, inflammatory responses and spontaneous pain-related behaviour. Key measured parameters include paw withdrawal latency after thermal stimulation, tail flick latency, vocalization, jumping, mechanical withdrawal threshold, force threshold, paw volume, oedema, hind paw weight distribution, thermal preference or avoidance, time spent in specific temperature zones, postural asymmetry and pain-related changes in locomotion or vertical activity.

These readouts help researchers assess hyperalgesia, allodynia, inflammatory pain, joint pain, neuropathic pain, post-surgical pain and treatment effects across different rodent models. By combining evoked responses with spontaneous behavioural endpoints, preclinical pain research can capture both stimulus-induced sensitivity and more naturalistic pain-related impairment. Ugo Basile’s pain portfolio includes instruments for thermal, mechanical, inflammatory and spontaneous pain assessment, including Plantar Test, Dynamic Plantar Aesthesiometer, Hot/Cold Plate, Electronic Von Frey, Plethysmometer, Librae Incapacitance Tester and Climbing Test.

Ugo Basile instruments for pain and inflammation research

Since 1963, Ugo Basile has supported pain and inflammation research with instruments designed to measure nociceptive thresholds, hypersensitivity, inflammatory responses and spontaneous pain-related behaviour in rodents.

Ugo Basile offers a complete portfolio of instruments for preclinical pain and inflammation research, covering thermal, mechanical, inflammatory and spontaneous pain-related endpoints.

Ugo Basile devices for thermal stimulation

The Plantar Test is used for thermal hyperalgesia studies through radiant heat stimulation of the hind paw and automatic paw-withdrawal detection. It is the gold standard for Thermal Hyperalgesia tests in unrestrained animals. The Tail Flick measures nociceptive thresholds to infrared heat stimulation of the tail and is especially suited to rapid, reflex-based analgesic screening with possibility to run repeated tests thanks to the lack of learning being the tail flick a reflexive response. The Hot/Cold Plate supports hot and cold sensitivity studies, including constant temperature, ramping and complex temperature protocols, while the Thermal Place Preference and Thermal Gradient Ring allow researchers to evaluate thermal preference and avoidance in freely moving animals. Both systems involve a cognitive component and in fact repeated tests on the same animal are subject to hyper- or hypo- responses due to previous test experience.

Orofacial Stimulation measures hypersensitivity to thermal (hot and cold) and/or mechanical stimulation of the orofacial area in rats (mouse adaptor available) and is used for research into a wide range of pain conditions involving the trigeminal nerve with no need to cut vibrissae.

Ugo Basile devices for evoked mechanical stimulation

For mechanical sensitivity, the Dynamic Plantar Aesthesiometer provides automated force application and paw-withdrawal scoring for mechanical allodynia studies, while the Electronic Von Frey and Von Frey Filaments support mechanical threshold assessment across different force ranges. The PAM – Pressure Application Measurement system is designed for joint pain and arthritis models, enabling direct quantifiable stimulation of rodent joints. However the PAM can also be used with specific applicators for other parts of the body from the paws to the back and spinal chord, etc. Analgesy-Meter is typically used for inflammatory conditions to measure to measure mechanical sensitivity and pain threshold of pressure applied on mic or rat paw for basic or applied research or phenotyping.

Ugo Basile spontaneous pain apparatus

The Climbing Test adds a vertical activity endpoint for spontaneous pain, motor function and activity-related studies. Librae Incapacitance Tester assesses hind paw weight distribution as an objective measure of spontaneous pain. Plethysmometer measures paw volume and oedema.

Frequently Asked Questions

What instruments are used to measure pain in rodents?

Rodent pain can be assessed using different instruments depending on the type of pain response being studied. Thermal pain is commonly measured with plantar stimulation systems, tail flick meters, hot/cold plates, thermal place preference systems and thermal gradient paradigms. Mechanical sensitivity is assessed with dynamic plantar aesthesiometers, electronic Von Frey devices, manual Von Frey filaments, paw pressure systems and joint pressure tools. Spontaneous pain and inflammation can be evaluated through weight-bearing asymmetry, paw volume measurement, gait analysis and activity-based readouts.