IR-transparent mazes for video-tracking
Ugo Basile Infrared transparent mazes offer the highest contrast for the best video-tracking performance, empowering your behavioral experiments.
The new 2025 version of Startle/PPI system has been recently upgraded to provide enhanced precision, flexibility, and ease of use.
The main improvements include:
The latest software version includes:
Startle Prepulse Inhibition (PPI) is an experimental paradigm commonly used in rodents, such as mice and rats, to study sensorimotor gating, which refers to the brain's ability to filter out irrelevant sensory stimuli and prevent them from overwhelming the processing of more important stimuli.
Sensorimotor gating refers to the ability of a sensory event to suppress or decrease a motor response, in this case, a startle response
The Startle PPI paradigm has been widely used in neuroscience research to study sensorimotor gating deficits in different animal models, including genetic mouse models and those induced by pharmacological agents. It has also been employed to investigate the neural mechanisms underlying sensorimotor gating and to evaluate the effects of potential therapeutic interventions for disorders like schizophrenia, where PPI deficits are often observed.
A typical experiment includes a startle baseline measurement as a response to a lound sound (more rarely to a light or air-puff). A pre-pulse stimulus is delivered shortly before the loud stimulus and is supposed to decrease the startle reaction in healthy animals. Normally the time between trials is randomized to ensure that the animal response is not influenced by previous stimuli.
Researchers can manipulate various experimental parameters to investigate the factors influencing PPI, such as the intensity of the prepulse, the interval between the prepulse and startle stimulus (known as the prepulse-to-pulse interval or PPI interval), and the genetic or pharmacological manipulations of the animals.
As data analysis, the pulse alone startle reflex provides an index of the animal reaction to the startle pulse in terms of maximal peak, the pre-pulse alone startle reflex provides an index of the animal reaction to the pre-pulse startle in terms of maximal peak and the %PPI indicates the inhibition of the startle reflex.
The %PPI is calculated as the decrease of the startle response after the pre-pulse is delivered, divided by the startle amplitude and is calculated for each of the pulse intensities).
The Ugo Basile system is fully automated both for the preparation of the procedure and for the analysis of data. Main features include:
Different animal holders to match animal dimensions.
Features | Benefits |
---|---|
Maximum Flexibility, full event randomization |
Configure your own Experimental Schedules directly on your PC |
User-friendly software included |
Exceptional flexibility and intuitivity in the software protocol building |
Multiple stimuli |
The user can decide to use pre-pulses and pulses with white noise, frequency noise, light, air puff |
Multiple cage system | High throughput with up to 4 cages running at the same time |
Cubicle ready for FC | Just add a grid cage, camera and software and all electronics is already on-board to add Fear Conditioning seamlessly |
Graphical programming | Even the most complex protocols can be written without a single line of code but just with intruitive “block building” mode |
General | |
---|---|
Power Requirements |
Universal input 100-240 VAC, 50-60Hz, 60W |
Sound Level + Whitenoise |
< 60 dB |
Operating environment |
10°C to 40°C; 5% to 95% RH (non-condensing) |
Operation | |
Sound Range |
From 65 dB to 120 dB |
Pulse/pre pulse sound range (at 3KHz) | From 65 dB to 120 dB |
Modulated Sound Frequency Range | From 100 Hz to 18 KHz |
Airpuff |
Air Puff stimulus complete system add-on |
IR Light |
0-100% (Environment) |
Flash Light |
0-100% (20K Lux) S/R Platform) |
Data Export |
.csv, .xlsx format
|
Number of cages | Up to 4 |
PC Requirements | Windows 64-bit environment – Intel Core i7 processor or higher, 8GB RAM |
Physical | |
Cubicle Dimensions - Outside | 52(d)x62(w)x58(h)cm |
Cubicle Dimensions - Inside |
39(d)x47(w)x49(h)cm |
Restrainer Dimensions | |
---|---|
48003 - Set of two Mouse Holders for Startle/PPI |
Small Mouse: Internal Dimension 40x90x40(h)mm Large Mouse: ID 45x90x45(h)mm |
48003-360 Restrainer for rodents up to 100gr |
Internal length: adjustable from 39-89 mm Internal diameter: 50 mm |
48003-370 Restrainer for rodents from 100gr to 250gr |
Internal length: adjustable from 53-133 mm Internal diameter: 76 mm |
48003-390 Restrainer for rodents from 450gr to 800gr |
Internal length: adjustable from 75.5-178 mm Internal diameter: 113 mm |
48003-380 Restrainer for rodents from 250gr to 450gr |
Internal length: adjustable from 90.5-213 mm Internal diameter: 90 mm |
Warranty | |
Warranty | Startle PPI is covered by a 12-month warranty + 12 after product registration |
Startle PPI devices for mice and rats have a wide range of applications in neuroscience and behavioral research, allowing scientists to study sensorimotor gating, its modulation by various factors, and its relevance to neuropsychiatric and neurological conditions.
Several clinical studies have shown that a number of human disorders have impaired PPI including: schizophrenia, Huntington’s disease, fragile X syndrome, and autism. Utilization of Startle PPI tests in rodents has a translational value to assess the effects of a number of treatment modalities such as putative anti-psychotics, and to explore genetic and neurobiological mechanisms underlying behaviors of relevance to psychosis.
In behavioral phenotyping PPI devices are normally part of a battery of tests for cognitive function, especially to relate sensorimotor gating to learning and memory. In Pharmacology and Drug discovery PPI is often used to test the effect of drugs on sensorymotor gating and to screen compounds in early development phase or to test the effect of toxic agents. In stress and anxiety research, PPI has shown a relationship between these conditions and sensorimotor gating.
Two Animal Startle/PPI Systems: | ||
---|---|---|
48101-2 | Two animal Startle/PPI system (cubicle, sound, IR/visible light and software) to be completed with Mouse/Rat Platform and restrainers. Not compatible with previous system | |
To complete the Startle/PPI System, it’s necessary to choose one of the following platforms, according to the animal used for the experiment: | ||
48008 |
Startle PPI Mouse Platform V3, including set of two Mouse Restrainers |
|
48009 | Startle PPI Rat Platform V3, to be completed with Rat Restrainers | |
To complete Startle/PPI platform 3.0 for Rat (SKU 48009) choose between one of the available Rat Restrainers: | ||
48003-360 |
Startle PPI Cylindrical Rat Restrainer (up to 100gr) |
|
48003-370 | Startle PPI Cylindrical Rat Restrainer (up to 250gr) | |
48003-390 | Startle PPI Cylindrical Rat Restrainer (up to 450gr) | |
48003-380 | RStartle PPI Cylindrical Rat Restrainer (up to 800gr) | |
Optional items | ||
48000-200 |
4-Channel Air-Puff Dispenser, for Startle/PPI System. It requires connection to a cylinder or a gas line, with reducer. Each Startle/PPI unit requires in addition one kit 48000-204 including delivery system to stimulate animal with air. |
|
48000-204 | Air-puff kit, for each Startle/PPI Unit, to be attached to dispenser 48000-200. It includes all accessories for air delivery, except the animal cage (48003, two cage kit) | |
47400-050 | B/W USB Camera, including 2.1mm & 4.3mm lenses with visible light block filter, M12 Lens Adaptor, 2m USB cable and cubicle ceiling support (for Fear Conditioning 46101) | |
Available Spare Parts | ||
48003 | Set of two rectangular Mouse Restrainers for Startle/PPI | |
48008 | Startle PPI Mouse Platform V3, including set of two Mouse Restrainers | |
48009 | Startle PPI Rat Platform V3, to be completed with Rat Restrainers | |
48003-360 | Startle PPI Cylindrical Rat Restrainer (up to 100gr) | |
48003-370 | Startle PPI Cylindrical Rat Restrainer (up to 250gr) | |
48003-390 | Startle PPI Cylindrical Rat Restrainer (up to 450gr) | |
48003-380 | Startle PPI Cylindrical Rat Restrainer (up to 800gr) |
UB Care Additional Warranty Extension | ||
---|---|---|
48101-2-UBC12 | UB Care 12 Additional hardware warranty extension 12 months for Startle PPI (Valid for SKU 48101-2) | |
48101-2-UBC24 | UB Care 24 Additional hardware warranty extension 24 months for Startle PPI (Valid for SKU 48101-2) |
Bilel, S. et al. (2025), “Acute Effects of the Psychedelic Phenethylamin* 25I-NBOMe in C57BL/6J Male Mice”. International Jourmal of Molecular Sciences
Bassi. M. et al. (2024), “Pharmaco-toxicological effects of the novel tryptamin* hallucinoge* 5-MeO-MiPT on motor, sensorimotor, physiological, and cardiorespiratory parameters in mice—from a human poisoning case to the preclinical evidence”, Psychopharmacology
Corli, G. et al. (2023), “MAM‑2201 acute administration impairs motor, sensorimotor, prepulse inhibition, and memory functions in mice: a comparison with its analogue AM‑2201”, Psychopharmacology
Tirri, M. et al. (2022), “Effect of -NBOMe Compounds on Sensorimotor, Motor, and Prepulse Inhibition Responses in Mice in Comparison With the 2C Analogs and Lysergic Acid Diethylamide: From Preclinical Evidence to Forensic Implication in Driving Under the Influence of Drugs”, Frontiers in Psychiatry
Marti, M. at al. (2021) “New insights into methoxetamine mechanisms of action: Focus on serotonergic 5-HT2 receptors in pharmacological and behavioral effects in the rat”, Experimental Neurology
Tirri, M. et al. 2020, “Acute DOB and PMA Administration Impairs Motor and Sensorimotor Responses in Mice and Causes Hallucinogenic E cts in Adult Zebrafish”, Brain Sciences
Bilel, S,. et al. 2019, “Pharmacological and Behavioral Effects of the Synthetic Cannabinoid AKB48 in Rats”, Frontiers in Neuroscience
Braff, D. L. et al. 2001, “Human studies of prepulse inhibition of startle: normal subjects, patient groups, and pharmacological studies”, Psychopharmacology
M. Koch: “The Neurobiology of Startle” Prog Neurobiol. 59(2):107-28, 1999
H.S. Hoffman, M. Fleshker, 1963, “Startle Reaction: Modification By Background Acoustic Stimulation”, Science
R.R. Marsh et alia: “The Role of Small Changes in the Acoustic Environment in Modifying the Startle Reflex” J Exp Psychol Anim Behav Process, 1(3): 1975
In addition to the one-year Regular Warranty and in addition to the one-year product registration extended warranty, Ugo Basile offers an Optional Extended Warranty that extends the warranty period for the product for additional one or two years called “UB Care12”/“UB Care24”. Customers may purchase the “UB Care” at the maximum of 3 months after buying. For more detailed information, please contact your local representatives.
Thermal Conditioned Cabinet is an essential accessory for your TGR setup. It ensures optimal and stable environmental temperature from 0° up to 70° C (32° up to 158°F), improving test reliability and operator comfort. It holds up to two TGR units and provides insulation from light and noise, with built-in air suction and full connectivity to ANY-maze.
Thermal Conditioned Cabinet is an essential accessory for your TGR setup. It ensures optimal and stable environmental temperature from 0° up to 70° C (32° up to 158°F), improving test reliability and operator comfort. It holds up to two TGR units and provides insulation from light and noise, with built-in air suction and full connectivity to ANY-maze.