Quote list0
Your product list is empty!

Animal
Mouse, Rat

Tail Flick Unit - Thermal stimulation, D'Amour & Smith method

Product Code:37560

Accurately measures the nociceptive threshold to infrared heat stimulus on the rat or mouse tail. Used for rapid screening of analgesic drugs by measuring reaction time to heat, even in anesthetized animals, crucial for repeated tests, thanks to the reflexive nature of the tail flick response.

Adjustable I.R. intensity, bright touch-screen display with intuitive controls. Comfortable surface for the animal. Latency and thermal intensity data are automatically saved.

Model
Optional Please see "Ordering Information" for more details. For special requests use "Notes and Special Requests" section on the quote confirmation page.
An extended warranty can be added for most Ugo Basile products. You can find this information in the ordering information section of each product.
To learn more about the extended warranty, CLICK HERE

Background

  • Performs rapid precise screening of analgesic drugs via heat stimulation according to D’Amour & Smith method.
  • More than 3,000 citations of our Tail Flick unit in published papers. 
  • Market leading device is the most used and validated worldwide.

Easy use, excellent reproducibility

  • Works by focusing radiant energy of adjustable intensity on the animal tail (using an embodied parabolic mirror). 
  • Operator holds the animal on a comfortable, flat, unobstructed surface. 
  • Optional inclined mouse restrained is available to ensure flat tail position on surface (to compensate for mouse tendency to hold tail upwards).
  • When the animal flicks its tail in response to the pain, the sensor detects it, stops the timer and switches off the bulb.
  • Reaction time (latency) and light intensity data are saved automatically to the unit, USB key (supplied) or “one-touch” export to your PC.
  • Features a bright graphical touch screen with intuitive controls for easy use.
  • Easy start, convenient foot pedal switch for excellent reproducibility.
  • Includes Xpad software.

 

FeatureBenefits
Tail-flick is scored automatically or manually Precise score, free of human variability and flexibility
Fully controlled by a 4.3" touch screen Ultra-intuitive menus and bright colors for ease of use
USB memory key and software are included Works as a stand-alone or connected to the PC
No protruding elements and unobstructed surface Work confortably and get excellent reproducibility
Radiant energy can be calibrated with optional Radiometer   Arbitrary units can be converted and lamp usage compensated
 
 
General
Command input and read-out 4.3" colour touch screen
Power requirements Universal input 100-240 VAC, 50-60Hz, 50W
Sound Level <54db
Operating Environment 10°C to 40°C, 5% to 95% RH (non-condensing)

 

Operation

Data export .csv format via USB key
Start Experiment Via pedal switch or via start icon on the touch screen (or via TTL)
Stop Experiment Via pedal switch,  start icon on the touch screen, cut-off (or via TTL)
Measurement mode Manual (foot-switch) or automatic (fiber optic)
I.R. Intensity Adjustable in the interval 01-99 (in one digit steps)
Latency Time Displayed on the graphic display, in 0.1s steps
Cut-off Function Adjustable from 5 to 30 seconds
Data Portability  Via USB pen-drive provided
Calibration Via appropriate I.R. Radiometer (not included)
TTL/IO Available as input or output

 

Physical

Total Weight 2.8Kg
Shipping Weight 3Kg approx.
Dimensions 37.5(w) x38.5 (d) x 13 (h) cm (assembled)
Packing Dimensions 46x35x28cm

 

Warranty

Warranty Tail Flick Unit is covered by a 12-month warranty + 12 after product registration.
UB-Care Additional UB-Care can be added for other 12 or 24 months

The Tail Flick Unit basically consists of an IR source, whose radiant energy of adjustable intensity is focused by an embodied parabolic mirror on the animal tail. 

The animal is held by the operator on the instrument unobstructed upper panel in such a way that its tail, placed over a flush mounted window, receives the IR energy. The operator starts the stimulus and the related reaction-time counter by the pedal switch or by the touch-screen start button. When the animal feels pain and flicks its tail, a sensor detects it, stops the reaction time counter and switches off the bulb. The reaction time of the animal is thus automatically determined to the nearest 0.1 second.

(unless the manual score option is activated, in which case it is the scientist to stop the counter by pressing the footswitch).

37560 Tail Flick Unit
37560-001 Tail Flick Main Unit
37215-303 Pedal Switch
E-AU 101 USB Pen Drive

 

Optional

 
37360-325 Mouse Holder (25mm I.D.)
37360-330 Mouse Holder (30mm I.D.)
37300 Heat-Flux I.R. Radiometer for calibration
Back to: Pain and Inflammation

Research insights

Preclinical research in pain and inflammation

Pain affects an estimated 20% of adults worldwide, with millions of new chronic pain cases diagnosed every year. Yet, it remains insufficiently addressed as a major public health issue. Recognizing pain as a complex condition influenced by biological, social and environmental factors is essential to improve research, prevention, treatment and health policies.

Developing safer and more effective pain management strategies requires a deeper understanding of the biological mechanisms underlying pain and inflammation. In this context, preclinical research plays a fundamental role in identifying therapeutic targets, evaluating novel treatments and generating evidence to support translation into clinical practice.

Most used paradigms for pain and inflammation research

Pain and inflammation research uses a combination of evoked and spontaneous paradigms to assess nociception, hypersensitivity, inflammatory responses and pain-related impairment in rodents. Evoked thermal paradigms include plantar stimulation, tail flick, hot/cold plate testing, thermal place preference and thermal gradient assessment, which are used to investigate heat sensitivity, cold sensitivity, thermal hyperalgesia, allodinya and thermal preference or avoidance.

Mechanical paradigms include dynamic plantar stimulation, electronic or manual Von Frey testing, paw pressure testing and direct joint pressure application, supporting the assessment of mechanical allodynia, hyperalgesia and joint hypersensitivity. Spontaneous pain paradigms include weight-bearing asymmetry, postural imbalance, vertical activity and gait or locomotor changes, which are particularly relevant in arthritis, neuropathic pain, bone cancer pain, post-surgical pain and inflammatory models.

Inflammation can also be evaluated as a dedicated endpoint through paw volume and oedema measurement, allowing researchers to quantify experimentally induced swelling and pharmacological treatment effects.

Specific pain conditions like the ones involving the Trigeminal nerve are assessed by dedicated devices for thermal and mechanical stimulation of the animal vibrissae area, during the Orofacial Test.

Key behavioral readouts in pain assessment

Pain and inflammation studies rely on behavioural readouts that quantify nociceptive thresholds, hypersensitivity, inflammatory responses and spontaneous pain-related behaviour. Key measured parameters include paw withdrawal latency after thermal stimulation, tail flick latency, vocalization, jumping, mechanical withdrawal threshold, force threshold, paw volume, oedema, hind paw weight distribution, thermal preference or avoidance, time spent in specific temperature zones, postural asymmetry and pain-related changes in locomotion or vertical activity.

These readouts help researchers assess hyperalgesia, allodynia, inflammatory pain, joint pain, neuropathic pain, post-surgical pain and treatment effects across different rodent models. By combining evoked responses with spontaneous behavioural endpoints, preclinical pain research can capture both stimulus-induced sensitivity and more naturalistic pain-related impairment. Ugo Basile’s pain portfolio includes instruments for thermal, mechanical, inflammatory and spontaneous pain assessment, including Plantar Test, Dynamic Plantar Aesthesiometer, Hot/Cold Plate, Electronic Von Frey, Plethysmometer, Librae Incapacitance Tester and Climbing Test.

Ugo Basile instruments for pain and inflammation research

Since 1963, Ugo Basile has supported pain and inflammation research with instruments designed to measure nociceptive thresholds, hypersensitivity, inflammatory responses and spontaneous pain-related behaviour in rodents.

Ugo Basile offers a complete portfolio of instruments for preclinical pain and inflammation research, covering thermal, mechanical, inflammatory and spontaneous pain-related endpoints.

Ugo Basile devices for thermal stimulation

The Plantar Test is used for thermal hyperalgesia studies through radiant heat stimulation of the hind paw and automatic paw-withdrawal detection. It is the gold standard for Thermal Hyperalgesia tests in unrestrained animals. The Tail Flick measures nociceptive thresholds to infrared heat stimulation of the tail and is especially suited to rapid, reflex-based analgesic screening with possibility to run repeated tests thanks to the lack of learning being the tail flick a reflexive response. The Hot/Cold Plate supports hot and cold sensitivity studies, including constant temperature, ramping and complex temperature protocols, while the Thermal Place Preference and Thermal Gradient Ring allow researchers to evaluate thermal preference and avoidance in freely moving animals. Both systems involve a cognitive component and in fact repeated tests on the same animal are subject to hyper- or hypo- responses due to previous test experience.

Orofacial Stimulation measures hypersensitivity to thermal (hot and cold) and/or mechanical stimulation of the orofacial area in rats (mouse adaptor available) and is used for research into a wide range of pain conditions involving the trigeminal nerve with no need to cut vibrissae.

Ugo Basile devices for evoked mechanical stimulation

For mechanical sensitivity, the Dynamic Plantar Aesthesiometer provides automated force application and paw-withdrawal scoring for mechanical allodynia studies, while the Electronic Von Frey and Von Frey Filaments support mechanical threshold assessment across different force ranges. The PAM – Pressure Application Measurement system is designed for joint pain and arthritis models, enabling direct quantifiable stimulation of rodent joints. However the PAM can also be used with specific applicators for other parts of the body from the paws to the back and spinal chord, etc. Analgesy-Meter is typically used for inflammatory conditions to measure to measure mechanical sensitivity and pain threshold of pressure applied on mic or rat paw for basic or applied research or phenotyping.

Ugo Basile spontaneous pain apparatus

The Climbing Test adds a vertical activity endpoint for spontaneous pain, motor function and activity-related studies. Librae Incapacitance Tester assesses hind paw weight distribution as an objective measure of spontaneous pain. Plethysmometer measures paw volume and oedema.

Frequently Asked Questions

What instruments are used to measure pain in rodents?

Rodent pain can be assessed using different instruments depending on the type of pain response being studied. Thermal pain is commonly measured with plantar stimulation systems, tail flick meters, hot/cold plates, thermal place preference systems and thermal gradient paradigms. Mechanical sensitivity is assessed with dynamic plantar aesthesiometers, electronic Von Frey devices, manual Von Frey filaments, paw pressure systems and joint pressure tools. Spontaneous pain and inflammation can be evaluated through weight-bearing asymmetry, paw volume measurement, gait analysis and activity-based readouts.